CBLC Antibody

Shipped with Ice Packs
In Stock

Product Specs

Buffer
PBS with 0.1% Sodium Azide, 50% Glycerol, pH 7.3. Store at -20°C. Avoid freeze / thaw cycles.
Lead Time
Typically, we can ship the products within 1-3 business days after receiving your order. Delivery times may vary depending on the shipping method and destination. Please contact your local distributor for specific delivery information.
Synonyms
CBLC antibody; CBL3 antibody; RNF57E3 ubiquitin-protein ligase CBL-C antibody; EC 2.3.2.27 antibody; RING finger protein 57 antibody; RING-type E3 ubiquitin transferase CBL-C antibody; SH3-binding protein CBL-3 antibody; SH3-binding protein CBL-C antibody; Signal transduction protein CBL-C antibody
Target Names
Uniprot No.

Target Background

Function
CBLC acts as an E3 ubiquitin-protein ligase. It receives ubiquitin from specific E2 ubiquitin-conjugating enzymes and then transfers it to substrates, promoting their degradation through the proteasome. CBLC is functionally linked to the E2 ubiquitin-protein ligases UB2D1, UB2D2, and UB2D3. It serves as a regulator of EGFR-mediated signal transduction. Upon EGF activation, CBLC ubiquitinates EGFR. Notably, isoform 1, but not isoform 2, inhibits EGF-stimulated MAPK1 activation. Furthermore, CBLC promotes the ubiquitination of SRC phosphorylated at 'Tyr-419'. In collaboration with CD2AP, CBLC may function as a regulatory checkpoint for Ret signaling by modulating the rate of RET degradation after ligand activation. CD2AP shifts CBLC from an inhibitor to a promoter of RET degradation, limiting the potency of GDNF on neuronal survival.
Gene References Into Functions
  1. Methylmalonic aciduria with homocystinuria cblC is a multisystemic metabolic disease affecting cobalamin metabolism. The presence of retinal alterations in cblC is a common feature and is reported to develop more frequently and into a more severe form in the early-onset phenotype, suggesting a correlation with the biochemical phenotype. PMID: 28481040
  2. Research suggests that ubiquitin ligase CBLC primarily controls the network organization of the Golgi Apparatus. PMID: 26393512
  3. Silencing of CBLC leads to increased sensitivity to PARP1 inhibitor olaparib in breast cancer cell line models. Defective homologous recombination (HR) DNA repair is likely the underlying cause. PMID: 25883215
  4. Studies have examined the effects of two pathogenic missense mutations on the catalytic activities of the human B12-processing chaperone CblC. PMID: 25809485
  5. This retrospective multicentre study evaluates clinical, biochemical, and genetic findings in 88 cblC patients. PMID: 24599607
  6. The ubiquitin ligase activity of Cbl-c is demonstrated through the direct interaction of the LIM zinc coordinating domain of Hic5. PMID: 23145173
  7. The N terminus of Cbl-c contributes to binding to the E2. Phosphorylation of Tyr-341 leads to a decrease in affinity and an increase in the E3 activity of Cbl-c. PMID: 20525694
  8. Data indicates that two E3 ligases of different classes, CBLC and AIP4, can interact and cooperate to down-regulate EGFR signaling. PMID: 12226085
  9. c-Cbl is a negative regulator of hepatocyte growth factor/receptor tyrosine kinase Met signaling in B cells. It mediates ubiquitination and subsequent proteosomal degradation of Met, playing a role in Met-mediated tumorigenesis. PMID: 12244174
  10. Src is a preferential target of Cbl-c for degradation. PMID: 14661060
  11. Ubiquitin protein ligase activity is regulated in c-Cbl by phosphorylation-induced conformational change and constitutive activation by tyrosine to glutamate point mutations. PMID: 15117950
Database Links

HGNC: 15961

OMIM: 608453

KEGG: hsa:23624

STRING: 9606.ENSP00000270279

UniGene: Hs.466907

Tissue Specificity
Ubiquitous.

Q&A

What is CBLC and why is it important in research?

CBLC (Cbl proto-oncogene C) is a human protein also known as Cas-Br-M ecotropic retroviral transforming sequence c, CBL-3, CBL-SL, RNF57, or E3 ubiquitin-protein ligase CBL-C. The protein has a molecular weight of approximately 52.5 kilodaltons and functions as an E3 ubiquitin-protein ligase. CBLC plays significant roles in protein ubiquitination pathways, receptor downregulation, and cell signaling processes, making it relevant to cancer research, cell biology, and signal transduction studies. The protein has orthologs in multiple species including canine, porcine, monkey, mouse, and rat, enabling comparative studies across model organisms .

What criteria should I use when selecting a CBLC antibody for my research?

When selecting a CBLC antibody, consider several critical factors: (1) Target specificity - verify the epitope region and whether the antibody recognizes specific domains of CBLC; (2) Host species compatibility - ensure the host species doesn't conflict with other antibodies in multiplex experiments; (3) Validated applications - confirm the antibody has been validated for your specific application (WB, IF, IHC, etc.); (4) Species reactivity - check whether the antibody recognizes your species of interest (human, mouse, rat, etc.); (5) Clonality - monoclonal antibodies offer higher specificity while polyclonals may provide stronger signals; (6) Published citations - review literature using the same antibody to assess reliability; and (7) Validation data - examine supplier-provided validation data including positive and negative controls .

How do I properly validate a CBLC antibody before using it in critical experiments?

Proper validation of a CBLC antibody should follow a multi-step approach: (1) Positive and negative controls - use samples with known CBLC expression levels and CBLC knockout/knockdown samples; (2) Molecular weight confirmation - verify that the detected band matches the expected 52.5 kDa size of CBLC; (3) Peptide competition assay - pre-incubate the antibody with immunizing peptide to confirm specificity; (4) Cross-reactivity testing - test against closely related proteins (e.g., other CBL family members); (5) Orthogonal validation - compare results with alternative detection methods like mass spectrometry or RNA expression; (6) Application-specific validation - optimize conditions for each specific application (WB, IF, IHC, etc.) separately; and (7) Reproducibility assessment - confirm consistent results across multiple experiments and biological replicates .

What are the optimal conditions for using CBLC antibodies in Western blot applications?

For optimal Western blot detection of CBLC, implement the following protocol: (1) Sample preparation - lyse cells in RIPA buffer supplemented with protease/phosphatase inhibitors; (2) Protein loading - use 20-40 μg of total protein per lane; (3) Gel selection - 8-10% polyacrylamide gels typically provide good resolution for the 52.5 kDa CBLC protein; (4) Transfer conditions - wet transfer at 100V for 1 hour or 30V overnight onto PVDF membrane; (5) Blocking - 5% non-fat dry milk or BSA in TBST for 1 hour at room temperature; (6) Primary antibody dilution - typically 1:1000 to 1:2000 in blocking buffer overnight at 4°C (optimize based on specific antibody); (7) Secondary antibody - use at 1:5000 to 1:10000 dilution for 1 hour at room temperature; (8) Washing - perform 3-5 washes with TBST for 5-10 minutes each; (9) Detection - use enhanced chemiluminescence with exposure times optimized for signal intensity .

How can I effectively use CBLC antibodies for immunofluorescence studies?

For effective immunofluorescence studies with CBLC antibodies: (1) Cell preparation - culture cells on coated coverslips at 60-70% confluence; (2) Fixation method - use 4% paraformaldehyde for 10-15 minutes, which preserves CBLC epitopes better than methanol fixation; (3) Permeabilization - 0.1-0.3% Triton X-100 for 5-10 minutes; (4) Blocking solution - 5% normal serum from the same species as secondary antibody in PBS with 0.1% Triton X-100 for 30-60 minutes; (5) Primary antibody incubation - dilute CBLC antibody 1:100 to 1:500 (optimize for each antibody) and incubate overnight at 4°C; (6) Secondary antibody - incubate for 1 hour at room temperature in the dark; (7) Nuclear counterstain - DAPI at 1 μg/ml for 5 minutes; (8) Mounting - use anti-fade mounting medium to preserve fluorescence; (9) Controls - include secondary-only controls and cells with known CBLC expression patterns .

What strategies can improve CBLC detection in immunohistochemistry of tissue samples?

To enhance CBLC detection in tissue immunohistochemistry: (1) Tissue fixation - use neutral buffered formalin and limit fixation time to preserve epitopes; (2) Antigen retrieval - perform heat-induced epitope retrieval using citrate buffer (pH 6.0) or EDTA buffer (pH 9.0) for 15-20 minutes; (3) Endogenous peroxidase blocking - 3% hydrogen peroxide for 10 minutes; (4) Protein blocking - use 5-10% normal serum or commercial blocking solutions for 30-60 minutes; (5) Primary antibody optimization - titrate concentrations between 1:50 to 1:500 and incubate overnight at 4°C; (6) Signal amplification - consider using polymer-based detection systems for enhanced sensitivity; (7) Counterstaining - light hematoxylin staining to preserve visibility of DAB signal; (8) Positive controls - include tissues with known CBLC expression patterns; (9) Antibody specificity controls - use peptide competition or isotype controls to confirm specificity; (10) Multi-step chromogenic development - monitor color development to optimize signal-to-noise ratio .

How can I design co-immunoprecipitation experiments to study CBLC protein interactions?

For effective co-immunoprecipitation of CBLC and its interacting partners: (1) Lysis buffer selection - use NP-40 or CHAPS-based buffers that maintain protein-protein interactions; (2) Pre-clearing step - incubate lysates with protein A/G beads to reduce non-specific binding; (3) Antibody selection - choose CBLC antibodies validated for immunoprecipitation applications with confirmed epitope accessibility; (4) Antibody immobilization - pre-conjugate antibodies to beads or use direct immunoprecipitation depending on antibody characteristics; (5) Incubation conditions - perform binding reactions at 4°C for 2-4 hours or overnight with gentle rotation; (6) Washing stringency - balance between preserving interactions and reducing background with 3-5 washes; (7) Elution strategy - use gentle elution with glycine buffer (pH 2.8) or direct SDS sample buffer depending on downstream applications; (8) Controls - include IgG control and input samples; (9) Reverse co-IP - confirm interactions by immunoprecipitating the suspected binding partner and blotting for CBLC; (10) Crosslinking consideration - evaluate whether chemical crosslinking would help stabilize transient interactions .

What approaches can detect post-translational modifications of CBLC protein?

To investigate post-translational modifications of CBLC: (1) Phosphorylation analysis - use phospho-specific antibodies or phos-tag gels to detect mobility shifts; (2) Ubiquitination detection - perform immunoprecipitation under denaturing conditions to disrupt non-covalent interactions followed by ubiquitin-specific western blotting; (3) SUMOylation assessment - use SUMO-specific antibodies after immunoprecipitating CBLC; (4) Mass spectrometry workflow - enrich for CBLC by immunoprecipitation, perform in-gel digestion with trypsin, and analyze peptides by LC-MS/MS for modifications; (5) Enrichment techniques - use phosphopeptide enrichment (TiO2 or IMAC) or ubiquitin remnant motif antibodies to enhance detection of modified peptides; (6) Site-directed mutagenesis - create point mutations at suspected modification sites to confirm functional significance; (7) Inhibitor studies - use kinase, phosphatase, or deubiquitinase inhibitors to manipulate modification states; (8) In vitro modification assays - reconstitute modification reactions with purified components to confirm direct effects .

How should I design experiments to study CBLC's role in receptor trafficking and degradation?

To investigate CBLC's function in receptor trafficking and degradation: (1) Pulse-chase experiments - label cell surface receptors and track internalization kinetics with and without CBLC manipulation; (2) Colocalization studies - perform dual immunofluorescence with CBLC antibodies and markers for different endocytic compartments (early endosomes, late endosomes, lysosomes); (3) Receptor degradation assays - perform cycloheximide chase experiments to measure receptor half-life in CBLC wildtype vs. knockdown/knockout conditions; (4) Ubiquitination analysis - immunoprecipitate receptors of interest and blot for ubiquitin to assess CBLC-dependent ubiquitination; (5) Dominant negative approaches - express CBLC mutants lacking E3 ligase activity to disrupt normal function; (6) Live cell imaging - use fluorescently-tagged receptors and CBLC to visualize trafficking dynamics in real-time; (7) Biochemical fractionation - separate cellular compartments to track receptor localization across conditions; (8) Functionality assays - measure downstream signaling outputs to assess receptor activity in different CBLC contexts .

How can I troubleshoot weak or absent CBLC signal in Western blots?

To address weak or absent CBLC signals in Western blots: (1) Sample preparation - confirm proper cell lysis by testing different lysis buffers and ensure sample freshness by adding protease inhibitors; (2) Protein denaturation - optimize sample heating conditions (70°C for 10 minutes often works better than boiling for CBLC); (3) Antibody validation - verify the antibody recognizes your species of interest and consider testing alternative antibodies targeting different CBLC epitopes; (4) Blocking optimization - test both milk and BSA as blocking agents as some antibodies perform better with specific blockers; (5) Incubation conditions - extend primary antibody incubation time to overnight at 4°C and optimize antibody concentration; (6) Detection sensitivity - switch to more sensitive detection methods such as enhanced chemiluminescence plus (ECL+) or fluorescent secondary antibodies; (7) Membrane optimization - try both PVDF and nitrocellulose membranes as protein binding characteristics differ; (8) Loading control verification - confirm sample integrity by blotting for housekeeping proteins; (9) Transfer efficiency - validate transfer by Ponceau S staining of membranes .

What are common sources of non-specific bands when using CBLC antibodies and how can they be eliminated?

Non-specific bands with CBLC antibodies can be addressed by: (1) Antibody specificity validation - perform peptide competition assays to identify truly specific bands; (2) Cross-reactivity analysis - determine if bands correspond to other CBL family members (CBL, CBLB) by comparing with their molecular weights and expression patterns; (3) Blocking optimization - increase blocking time/concentration or switch between milk and BSA to reduce non-specific binding; (4) Washing stringency - increase wash times and detergent concentration to remove weakly bound antibodies; (5) Secondary antibody controls - run secondary-only controls to identify bands caused by secondary antibody cross-reactivity; (6) Sample preparation - use more stringent lysis and denaturation conditions to reduce protein aggregates or fragments; (7) Antibody dilution - optimize primary and secondary antibody concentrations through titration; (8) Knockout/knockdown validation - use CBLC knockout or knockdown samples to definitively identify specific bands; (9) Pre-adsorption - pre-incubate antibodies with cell lysates from non-expressing cells to remove cross-reactive antibodies .

How can I distinguish between CBLC and other CBL family members in my experiments?

To differentiate between CBLC and other CBL family proteins: (1) Molecular weight discrimination - CBL (c-CBL) is approximately 120 kDa, CBLB is 110 kDa, and CBLC is 52.5 kDa, allowing separation on standard western blots; (2) Isoform-specific antibodies - select antibodies raised against unique regions with minimal sequence homology between family members; (3) Epitope mapping - determine the exact epitope recognized by your antibody and assess its conservation across CBL proteins; (4) Expression pattern analysis - leverage tissue-specific expression differences (CBLC shows more restricted expression compared to ubiquitous CBL); (5) Genetic approaches - use siRNA/shRNA specific to CBLC to confirm band identity through selective depletion; (6) Recombinant protein controls - run purified recombinant CBL proteins as size standards; (7) Immunoprecipitation followed by mass spectrometry - definitively identify proteins by peptide sequencing; (8) Domain-specific functional assays - design experiments exploiting unique functional properties of CBLC versus other family members .

How can CBLC antibodies be employed in cancer research and what methodological considerations are important?

For cancer research applications of CBLC antibodies: (1) Tissue microarray analysis - systematically assess CBLC expression across tumor types and correlate with clinical outcomes using optimized IHC protocols; (2) Patient-derived xenograft studies - track CBLC expression during tumor progression and treatment response using species-specific antibodies that distinguish human CBLC from host CBLC; (3) Biomarker development - standardize quantification methods for CBLC immunostaining using digital pathology approaches; (4) Signaling pathway analysis - combine CBLC antibodies with phospho-specific antibodies to map activation states of associated signaling proteins; (5) Drug response prediction - correlate CBLC expression or localization patterns with therapeutic efficacy in preclinical models; (6) Interaction proteomics - identify cancer-specific CBLC protein complexes using co-immunoprecipitation followed by mass spectrometry; (7) Cell type-specific analysis - use multiplexed immunofluorescence to examine CBLC expression in distinct cell populations within the tumor microenvironment; (8) Circulating tumor cell detection - explore CBLC as a potential marker for detecting and characterizing CTCs .

What are the methodological approaches for studying CBLC in neurodegenerative disease models?

To investigate CBLC in neurodegenerative disease contexts: (1) Brain region-specific analysis - optimize immunohistochemistry protocols for different brain regions with attention to fixation and antigen retrieval methods; (2) Cell type identification - perform co-localization studies with neuronal, glial, and microglial markers to determine cell type-specific expression; (3) Protein aggregation interaction - investigate CBLC association with disease-specific protein aggregates through proximity ligation assays; (4) CNS tissue preparation - modify standard protocols to account for high lipid content and complex morphology of neural tissues; (5) Primary neuron cultures - establish immunocytochemistry protocols for detecting endogenous CBLC in primary neurons with appropriate neuronal markers; (6) Blood-brain barrier considerations - when studying therapeutic antibodies, confirm BBB penetration through CSF sampling; (7) Microglial activation states - examine CBLC expression changes during different activation states of microglia; (8) Neuroinflammation correlation - assess relationships between inflammatory markers and CBLC expression patterns; (9) Axonal transport studies - investigate CBLC localization in axons and dendrites using high-resolution microscopy .

How can I apply CBLC antibodies in high-throughput screening or automated imaging platforms?

For high-throughput or automated imaging applications with CBLC antibodies: (1) Assay miniaturization - optimize antibody concentrations and incubation times for 96/384-well formats; (2) Signal-to-noise optimization - develop robust staining protocols with minimal background for automated image analysis; (3) Multiplex compatibility - verify antibody performance in multiplexed immunofluorescence assays with other markers of interest; (4) Automation adaptations - modify manual protocols for compatibility with liquid handling systems and washing stations; (5) Fixation standardization - establish consistent fixation methods that preserve CBLC epitopes while allowing high-throughput processing; (6) Image analysis parameters - develop algorithms for quantifying CBLC intensity, localization, and co-localization patterns; (7) Positive controls - incorporate on-plate controls with known CBLC expression patterns; (8) Z-factor calculation - determine assay quality through statistical analysis of positive and negative controls; (9) Normalization strategies - implement cell number normalization through nuclear counting or housekeeping protein measurement .

How do different detection methods compare for CBLC analysis, and when should each be used?

Comparing CBLC detection methodologies: (1) Western blotting - provides molecular weight verification and semi-quantitative analysis but requires cell lysis; optimal for measuring total protein levels and major PTMs; (2) Immunofluorescence - reveals subcellular localization and co-localization with other proteins while preserving cellular architecture; best for spatial distribution studies; (3) Immunohistochemistry - maintains tissue architecture and allows assessment of expression patterns in physiological/pathological contexts; preferred for clinical samples and in vivo studies; (4) Flow cytometry - enables quantitative single-cell analysis across large populations; ideal for heterogeneous samples and surface expression studies; (5) Proximity ligation assay - detects protein-protein interactions with high sensitivity; best for studying CBLC complexes in situ; (6) ELISA - provides quantitative measurement of CBLC in solution; suitable for serum/plasma studies or secreted variants; (7) ChIP - detects chromatin association if studying nuclear CBLC functions; (8) Mass spectrometry - offers unbiased detection of modifications and interacting partners but requires specialized equipment .

What experimental controls are essential when working with CBLC antibodies in different applications?

Essential controls for CBLC antibody experiments: (1) Specificity controls - CBLC knockout/knockdown samples or peptide competition assays to confirm antibody specificity; (2) Technical controls - secondary antibody-only samples to assess non-specific binding; (3) Isotype controls - matched isotype antibodies to evaluate background signals in flow cytometry or IHC; (4) Positive tissue/cell controls - samples with known CBLC expression to confirm detection sensitivity; (5) Loading controls - housekeeping proteins to normalize western blot signals; (6) Subcellular marker controls - established compartment markers to validate localization claims; (7) Expression controls - cells transfected with CBLC constructs as positive controls; (8) Treatment controls - pathway stimulation or inhibition with known effects on CBLC; (9) Cross-species controls - when using antibodies across species, positive controls from each species; (10) Batch controls - consistent control samples across experiments to account for inter-assay variation .

How do fixation and sample preparation methods affect CBLC epitope accessibility and detection sensitivity?

Impact of fixation and sample preparation on CBLC detection: (1) Fixative selection - paraformaldehyde (4%) generally preserves CBLC epitopes better than methanol, which can denature certain conformational epitopes; (2) Fixation duration - overfixation (>24 hours) can mask CBLC epitopes through excessive crosslinking; (3) Temperature effects - cold fixation (4°C) may better preserve certain labile epitopes but requires longer incubation; (4) Permeabilization optimization - Triton X-100 (0.1-0.3%) works well for cytoplasmic epitopes while methanol or saponin may be better for membrane-associated CBLC; (5) Antigen retrieval methods - heat-induced epitope retrieval using citrate buffer (pH 6.0) typically recovers most CBLC epitopes in FFPE tissues; (6) Proteolytic digestion - light enzymatic treatment can expose masked epitopes but risks destroying others; (7) Freeze-thaw effects - multiple freeze-thaw cycles of samples can reduce CBLC immunoreactivity; (8) Cell density considerations - overly confluent cultures may alter CBLC expression or localization; (9) Tissue thickness - optimize section thickness (4-7 μm) for balanced signal intensity and resolution .

How should I interpret changes in CBLC localization versus expression levels in response to experimental treatments?

Interpreting CBLC localization versus expression changes: (1) Comprehensive analysis - examine both total protein levels (by western blot) and subcellular distribution (by immunofluorescence) to distinguish between changes in expression versus translocation; (2) Subcellular fractionation - perform biochemical separation of cellular compartments followed by western blotting to quantify distribution shifts; (3) Live cell imaging - use fluorescently-tagged CBLC to track dynamic localization changes in real-time; (4) Co-localization metrics - calculate Pearson's or Mander's coefficients to quantify association with compartment markers before and after treatment; (5) Phosphorylation correlation - determine whether localization changes correlate with specific phosphorylation events; (6) Time-course experiments - establish the sequence of localization changes relative to expression changes; (7) Reversibility testing - determine whether changes persist after treatment withdrawal; (8) Dominant-negative approaches - use localization-defective CBLC mutants to probe functional significance of translocation; (9) Single-cell correlation - analyze whether expression level correlates with localization pattern at the single-cell level .

What statistical approaches are most appropriate for analyzing CBLC expression data across different experimental designs?

Statistical analysis of CBLC expression data: (1) For comparing two groups - utilize t-tests for normally distributed data or Mann-Whitney U tests for non-parametric distributions; (2) For multiple group comparisons - implement ANOVA with appropriate post-hoc tests (Tukey's or Dunnett's) or Kruskal-Wallis for non-parametric data; (3) For time-course experiments - apply repeated measures ANOVA or mixed-effects models to account for within-subject correlations; (4) For correlation analyses - use Pearson's correlation for linear relationships or Spearman's rank correlation for non-linear patterns; (5) For survival data - implement Kaplan-Meier analysis with log-rank tests when correlating CBLC expression with outcomes; (6) For multivariate analysis - use multiple regression or principal component analysis to assess CBLC in context of other variables; (7) For tissue microarray data - employ hierarchical clustering to identify expression patterns across sample types; (8) For high-dimensional data - implement false discovery rate control methods; (9) Sample size considerations - perform power analysis to determine appropriate sample sizes based on expected effect magnitude; (10) For categorical data - use chi-square or Fisher's exact tests when analyzing CBLC expression by categorical variables .

Quick Inquiry

Personal Email Detected
Please use an institutional or corporate email address for inquiries. Personal email accounts ( such as Gmail, Yahoo, and Outlook) are not accepted. *
© Copyright 2025 TheBiotek. All Rights Reserved.