cyt1 Antibody

Shipped with Ice Packs
In Stock

Description

Overview of Cyt1 Antibody

Cyt1 Antibody refers to a monoclonal antibody specifically targeting the Cyt1 cytoplasmic tail isoform of the CD46 protein (membrane cofactor protein), a complement regulatory protein involved in innate immunity and pathogen receptor functions . CD46 exists in isoforms with two distinct cytoplasmic tails (Cyt1 and Cyt2), which exhibit differential signaling and trafficking properties . The Cyt1 Antibody enables isoform-specific detection and functional studies, validated for applications including immunofluorescence microscopy, immunoblotting, and immunoprecipitation .

Key Features:

  • Specificity: No cross-reactivity with Cyt2 or unrelated peptides (validated via ELISA and immunoblotting) .

  • Applications:

    • Detects endogenous CD46-Cyt1 in human cell lines (e.g., A431, Chang) .

    • Identifies Cyt1 recruitment in pathogen-induced cortical plaques (e.g., Neisseria gonorrhoeae infection) .

    • Facilitates isoform-specific analysis of CD46 shedding and proteolytic processing .

Pathogen-Host Interactions

Cyt1 Antibody has been critical in studying CD46’s role as a receptor for pathogens:

  • Neisseria gonorrhoeae: Cyt1 clusters beneath bacterial microcolonies in cortical plaques, while Cyt2 remains peripheral (Table 1) .

  • Cleavage by Presenilin/γ-Secretase: Infection upregulates Cyt1 cleavage, producing 9 kDa and 6 kDa fragments detected via immunoprecipitation .

Table 1: Cyt1 vs. Cyt2 Recruitment in N. gonorrhoeae-Infected Cells

ParameterCyt1Cyt2
Plaque LocalizationCentral (pERM-positive)Peripheral
Detection Frequency100% (A431 cells)<10% (Chang cells)
Functional RoleImmune modulationTrafficking regulation
Data from

Technical Validation

  • Immunoblotting: Detects CD46-Cyt1 (~56 kDa) in lysates of human epithelial cells (Fig. 3 in ).

  • Immunofluorescence: Visualizes Cyt1 redistribution during pathogen adhesion .

  • Subclass Compatibility: IgG1 subclass allows multiplexing with other antibodies (e.g., IgG2a) .

Available Products

  • Clone 2F1 (MilliporeSigma): Validated for ELISA, flow cytometry, and immunoprecipitation; priced at $463.74 per unit .

  • Custom Recombinant Formats: Subclass-switched variants (e.g., IgG1/IgG2a) enhance multiplex assays .

Product Specs

Buffer
Preservative: 0.03% Proclin 300
Constituents: 50% Glycerol, 0.01M PBS, pH 7.4
Form
Liquid
Lead Time
14-16 weeks (Made-to-order)
Synonyms
cyt1; SPBC29A3.18; Cytochrome c1, heme protein, mitochondrial; Complex III subunit 4; Complex III subunit IV; Cytochrome b-c1 complex subunit 4; Ubiquinol-cytochrome-c reductase complex cytochrome c1 subunit; Cytochrome c-1
Target Names
cyt1
Uniprot No.

Target Background

Function
Cytochrome c1 is a catalytic core subunit of ubiquinol-cytochrome c oxidoreductase (complex III, CIII), a multi-subunit transmembrane complex within the mitochondrial electron transport chain (ETC). This complex plays a crucial role in oxidative phosphorylation. The ETC comprises three multi-subunit complexes: succinate dehydrogenase (complex II, CII), ubiquinol-cytochrome c oxidoreductase (complex III, CIII), and cytochrome c oxidase (complex IV, CIV). These complexes cooperatively transfer electrons from NADH and succinate to molecular oxygen. This process generates an electrochemical gradient across the inner mitochondrial membrane, driving transmembrane transport and ATP synthase activity. Complex III catalyzes electron transfer from ubiquinol to cytochrome c, coupling this redox reaction to proton translocation across the inner mitochondrial membrane via the Q cycle. This cycle involves the consumption of two protons from the mitochondrial matrix, the release of four protons into the intermembrane space, and the transfer of two electrons to cytochrome c. Cytochrome c1, containing a c-type heme, is a key catalytic component, transferring electrons from the [2Fe-2S] iron-sulfur cluster of the Rieske protein to cytochrome c.
Database Links
Protein Families
Cytochrome c family
Subcellular Location
Mitochondrion inner membrane; Single-pass membrane protein.

Q&A

What is the CYT1 antibody and what cytokines does it detect?

The CYT1 antibody refers to antibodies used in Cytokine Array C1 systems, which are designed to detect multiple human cytokines simultaneously. Based on current research platforms, these arrays can detect up to 23 distinct human cytokines including GCSF, GM-CSF, GRO alpha/beta/gamma, GRO alpha (CXCL1), IL-1 alpha (IL-1 F1), IL-2, IL-3, IL-5, IL-6, IL-7, IL-8 (CXCL8), IL-10, IL-13, IL-15, IFN-gamma, MCP-1 (CCL2), MCP-2 (CCL8), MCP-3 (MARC/CCL7), MIG (CXCL9), RANTES (CCL5), TGF beta 1, TNF alpha, and TNF beta (TNFSF1B) . These antibody-based detection systems employ a sandwich-based design principle on membrane solid supports and utilize chemiluminescence for detection, offering high sensitivity at the picogram per milliliter level .

What sample types are compatible with CYT1 antibody-based detection systems?

CYT1 antibody arrays are designed to be compatible with multiple biological sample types. Researchers can use cell culture supernatants, plasma, serum, tissue lysates, and cell lysates with these antibody arrays . This versatility makes the CYT1 antibody platform valuable for diverse research applications. When processing blood samples for antibody-based cytokine detection, it's recommended to process samples within 1 hour of collection to maintain sample integrity, as demonstrated in flow cytometry protocols that employ similar antibody-based detection principles .

How does the sensitivity of CYT1 antibody arrays compare to other detection methods?

CYT1 antibody arrays offer picogram-per-milliliter sensitivity with the specificity of sandwich ELISA techniques . This provides researchers with higher detection density than traditional ELISA, Western blot, or bead-based multiplex assays. The sandwich-based design principle enhances specificity while maintaining high sensitivity, allowing researchers to detect cytokines even at low concentrations. This is particularly important when working with limited sample volumes or when analyzing cytokines that are expressed at low levels under certain experimental conditions .

How should researchers optimize antibody titration for cytokine detection?

For optimal cytokine detection using antibody arrays, researchers should perform careful antibody titration to identify the concentration that maximizes the signal from positive populations while minimizing background signal from negative populations. This approach has been validated in flow cytometry studies using as little as 50 μL of peripheral blood per panel . For CYT1 antibody arrays, a similar optimization process is recommended to enhance signal-to-noise ratio. The titration process should include serial dilutions of the antibody followed by testing against known positive and negative controls to establish the optimal working concentration that provides maximum sensitivity without increasing non-specific binding .

What are the best approaches for normalizing data from CYT1 antibody arrays?

Data normalization is a critical step in analyzing results from CYT1 antibody arrays. Researchers should employ specialized analysis tools that enable automated sorting and averaging, background subtraction, and normalization . The recommended approach includes:

  • Background subtraction using negative control spots

  • Normalization to positive control spots or housekeeping proteins

  • Data plotting with appropriate statistical analysis

Many CYT1 antibody array kits are supported by Excel-based analysis tools specifically designed for each array type that automate these computations. These tools facilitate the extraction of numerical data from array images and perform advanced computations that are particularly valuable for quantitative arrays . When comparing samples across different arrays or experimental conditions, normalization to internal controls is essential for accurate interpretation of relative protein expression changes.

How can researchers address cross-reactivity concerns with cytokine antibodies?

Cross-reactivity is a significant concern in cytokine antibody research, particularly when working with structurally similar cytokines such as the GRO family (alpha/beta/gamma). To address this challenge, researchers should:

  • Validate antibody specificity using recombinant cytokine standards

  • Include appropriate blocking steps in protocols (typically using 10% skim milk or similar blocking agents, as used in anti-CYP2E1 antibody detection protocols)

  • Compare results across multiple detection methods when possible

  • Consider pre-absorbing antibodies with potentially cross-reactive proteins when working with complex samples

The sandwich-based design of cytokine arrays provides an additional layer of specificity compared to single-antibody approaches, as two antibodies must recognize different epitopes on the same cytokine for detection to occur . This design significantly reduces false positive results from cross-reactivity.

What is the minimum sample volume required for reliable cytokine profiling using CYT1 antibody arrays?

One of the key advantages of CYT1 antibody arrays is their ability to detect multiple cytokines simultaneously using minimal sample volumes. Based on analogous research in flow cytometry panels designed for longitudinal studies, reliable detection can be achieved with as little as 50 μL of peripheral blood per panel . For the CYT1 antibody array specifically, the membrane-based format allows for efficient protein capture and detection even with limited sample volumes. When sample availability is constrained, researchers can optimize protocols by:

  • Reducing incubation volumes while maintaining antibody concentration

  • Extending incubation times to enhance capture efficiency

  • Using gentle agitation during incubation to improve binding kinetics

  • Optimizing detection sensitivity through extended exposure times during chemiluminescence imaging

How should researchers approach longitudinal studies using cytokine antibody arrays?

Longitudinal studies present unique challenges for cytokine profiling, particularly regarding sample collection consistency and inter-assay variability. Based on validated approaches in immunological research, the recommended strategy includes:

  • Collect samples at consistent timepoints (ideally same time of day)

  • Process all samples using identical protocols and reagent lots when possible

  • Include common control samples across multiple assay runs to normalize inter-assay variation

  • Limit blood collection volume to no more than 10% of total blood volume for animal studies to prevent physiological alterations

For mouse models, collecting no more than 50 μL of peripheral blood per timepoint has been demonstrated as effective for longitudinal cytokine profiling without significantly impacting the animal's immune status . Similar principles apply to human longitudinal studies, where standardized collection and processing protocols are essential for reliable data interpretation.

What are the most effective strategies for detecting changes in low-abundance cytokines?

Detecting low-abundance cytokines presents a significant challenge in immunological research. For optimal detection using CYT1 antibody arrays, researchers should consider:

  • Sample pre-concentration techniques (if compatible with target stability)

  • Extended primary antibody incubation times (up to overnight at 4°C)

  • Enhanced chemiluminescence detection systems with longer exposure times

  • Digital signal enhancement through computational analysis tools

The high sensitivity of sandwich-based antibody arrays provides picogram-level detection capabilities, but optimization may be required for particularly low-abundance targets . In LPS-induced inflammation models, cytokine changes were successfully detected using 50 μL sample volumes, demonstrating that even subtle immune responses can be captured with optimized protocols .

How can researchers determine the appropriate sample size for cytokine profiling studies?

Sample size determination for cytokine profiling studies should account for the intrinsic variability of immune populations. Research validating flow cytometry panels for immune cell analysis has demonstrated approaches for assessing this variability . The recommended methodology includes:

  • Conducting a pilot study with a small number of samples (n=5-12) to assess intrinsic variability

  • Calculating coefficients of variation for each cytokine of interest

  • Performing power analysis based on expected effect sizes and observed variability

  • Incorporating biological replicates to account for donor-to-donor variation

Validation studies have shown that antibody-based detection systems are sensitive enough to detect changes in peripheral blood after immune challenges like LPS induction, and these findings can help determine appropriate sample sizes based on immune population variability .

What statistical approaches are most appropriate for analyzing multi-cytokine data from antibody arrays?

The analysis of multi-cytokine data from CYT1 antibody arrays requires sophisticated statistical approaches to account for multiple comparisons and potential correlations between cytokines. Recommended statistical methods include:

  • Multiple regression analysis for examining relationships between multiple variables, similar to approaches used in analyzing anti-CYP2E1 antibody levels in relation to factors like sex, exposure levels, and genetic factors

  • One-way or two-way ANOVA followed by appropriate post-hoc tests (e.g., Bonferroni or Steel-Dwass) for comparing across multiple groups

  • Multivariate analysis techniques such as principal component analysis or hierarchical clustering to identify patterns across multiple cytokines

  • Correlation analysis to identify relationships between different cytokines or between cytokines and clinical parameters

The Excel-based analysis tools available for antibody arrays facilitate many of these statistical approaches, including automated sorting and averaging, background subtraction, normalization, and data plotting .

How should researchers interpret changes in cytokine profiles in the context of autoimmune responses?

Interpreting cytokine profile changes in autoimmune contexts requires careful consideration of both direct cytokine effects and potential autoantibody interactions. Research on anti-CYP2E1 autoantibodies provides insights into this complex relationship . Key considerations include:

  • Evaluating whether cytokine changes precede or follow autoantibody production

  • Assessing the impact of genetic factors (such as HLA types) on cytokine expression patterns

  • Analyzing sex-based differences in cytokine responses and autoantibody levels

  • Considering the formation of immune complexes that may sequester cytokines or alter their detection

Studies have shown that factors like sex can significantly impact autoantibody levels, with women having higher anti-CYP2E1 antibody levels than men in certain contexts . Similar patterns may apply to cytokine profiles, highlighting the importance of sex-stratified analysis in autoimmune research.

How can CYT1 antibody arrays be integrated with other immunological techniques for comprehensive immune profiling?

For comprehensive immune system characterization, researchers can integrate CYT1 antibody arrays with complementary techniques:

  • Flow cytometry panels for cellular phenotyping alongside soluble cytokine detection

  • Transcriptomic analysis to correlate cytokine protein levels with gene expression

  • Functional assays to assess the biological activity of detected cytokines

  • Imaging techniques to localize cytokine production within tissues

Integrated approaches have been validated in models like LPS-induced lung inflammation, where both cellular immune changes and cytokine profiles were simultaneously assessed . This multi-modal approach provides a more complete picture of immune responses by connecting cellular sources with their secreted factors.

What are the considerations for using CYT1 antibody arrays in biomarker discovery research?

CYT1 antibody arrays offer powerful capabilities for biomarker discovery, particularly in disease contexts where multiple cytokines may be dysregulated. Key considerations include:

  • Sample stratification based on clinical parameters to identify disease-specific patterns

  • Longitudinal sampling to identify early versus late biomarkers

  • Integration with machine learning approaches for pattern recognition across multiple cytokines

  • Validation of candidate biomarkers in independent cohorts using orthogonal methods

The application of cytokine arrays for biomarker screening has been established as an effective approach for identifying key factors involved in biological processes . For optimal biomarker discovery, researchers should capture samples at multiple timepoints and include appropriate clinical controls matched for demographic factors like age and sex .

How can researchers validate the specificity of cytokine detection when working with complex biological samples?

Validating cytokine detection specificity in complex samples requires systematic approaches:

  • Immunodepletion studies using specific antibodies to remove target cytokines

  • Spike-in recovery experiments with recombinant standards

  • Comparison of results across multiple antibody clones or detection platforms

  • Correlation with biological activity using functional assays

In studies of anti-CYP2E1 antibodies, researchers validated specificity by comparing commercially available proteins with synthesized ones, finding significantly higher detection levels with the purified synthesized protein . Similar validation approaches should be applied to cytokine detection systems to ensure specificity in complex biological matrices.

Quick Inquiry

Personal Email Detected
Please use an institutional or corporate email address for inquiries. Personal email accounts ( such as Gmail, Yahoo, and Outlook) are not accepted. *
© Copyright 2025 TheBiotek. All Rights Reserved.