CYS5 Antibody

Shipped with Ice Packs
In Stock

Description

Definition and Mechanism

Cy5 antibodies are monoclonal or polyclonal antibodies that specifically recognize the Cy5 fluorophore. Cy5 emits in the far-red spectrum (excitation/emission: 649/670 nm), making it ideal for multiplexed imaging and assays with minimal autofluorescence interference . These antibodies bind Cy5 directly, facilitating the detection of Cy5-conjugated probes, antibodies, or other biomolecules in complex samples.

Development and Optimization

Cy5 antibodies are often engineered with enhanced sensitivity through conjugation strategies. For example:

  • Double-biotin DNA linkages amplify signals by increasing Cy5 density per binding event, improving detection limits to ≤9 CFU mL⁻¹ for pathogens like E. coli and Salmonella .

  • Streptavidin-Cy5 complexes are optimized at concentrations of 60 µg mL⁻¹ for maximal fluorescence intensity and minimal background noise .

Table 1: Key Optimization Parameters for Cy5 Antibody Complexes

ParameterOptimal ValueImpact on Performance
Cy5-streptavidin conc.60 µg mL⁻¹Maximizes signal-to-noise ratio
Double-biotin DNA80 fMEnhances binding efficiency
Storage stability90–105 days at 4°CRetains >90% activity

Foodborne Pathogen Detection

Cy5 antibody microarrays (ES-biochips) enable simultaneous detection of E. coli O157:H7 and S. typhimurium in food samples:

  • Limit of detection: 10³ CFU mL⁻¹ (visual) and <9 CFU mL⁻¹ (fluorescence) .

  • Specificity: No cross-reactivity with non-target bacteria like L. monocytogenes .

Clinical Diagnostics

  • Brain cancer imaging: Anti-Cy5 antibodies localize unquenched Cy5 probes to peri-tumor regions, correlating with cathepsin-L expression .

  • Flow cytometry: Cy5-conjugated antibodies (e.g., CD3, CD19) are used for immunophenotyping, though nonspecific binding to monocytes via FcγRI (CD64) can occur. This is mitigated using phosphorothioate oligodeoxynucleotides (PS-ODNs) .

Multiplex Assays

  • Microarray analysis: Cy5 antibodies enable high-throughput screening of gene expression and protein interactions .

Signal Amplification

Cy5-Ab complexes with double-biotin DNA linkages increase fluorescence signals by ~2× compared to conventional streptavidin-Cy5 conjugates .

Stability

  • Cy5-Ab complexes: Retain functionality for 90 days at 4°C .

  • Capture antibodies: Stable for 105 days under the same conditions .

Cross-Reactivity Solutions

PS-ODNs block nonspecific binding of Cy5 conjugates to monocytes by competitively inhibiting CD64 interactions .

Challenges and Future Directions

  • Photostability: Cy5 is prone to photobleaching, necessitating optimized imaging protocols .

  • Multiplexing: Spectral overlap with near-infrared dyes requires careful filter selection.

Product Specs

Buffer
Preservative: 0.03% Proclin 300
Constituents: 50% Glycerol, 0.01M PBS, pH 7.4
Form
Liquid
Lead Time
Made-to-order (14-16 weeks)
Synonyms
CYS5 antibody; At5g47550 antibody; MNJ7.14Cysteine proteinase inhibitor 5 antibody; AtCYS-5 antibody
Target Names
CYS5
Uniprot No.

Target Background

Function
CYS5 Antibody is a specific inhibitor of cysteine proteinases. It is likely involved in the regulation of endogenous processes and in defense against pests and pathogens.
Gene References Into Functions
  1. The abscissic acid-dependent pathway plays a positive role in the heat shock-responsive expression of AtCYS5 during seed germination and post-germination growth. [AtCYS5] PMID: 28756655
Database Links

KEGG: ath:AT5G47550

STRING: 3702.AT5G47550.1

UniGene: At.43346

Protein Families
Cystatin family, Phytocystatin subfamily
Subcellular Location
Secreted.

Q&A

What is Cy5 and why is it commonly used in antibody labeling?

Cy5 is a fluorescent dye belonging to the cyanine dye family that emits in the red region of the electromagnetic spectrum when excited by an appropriate light source. It has gained widespread popularity in molecular biology research due to its strong signal, high photostability, and compatibility with various imaging systems. These properties make Cy5 particularly valuable for antibody conjugation in applications requiring sensitive detection of biomolecules .

The molecular structure of Cy5 contains polymethine groups that contribute to its spectral characteristics, with maximum absorption at approximately 650 nm and emission at around 670 nm. This spectral profile positions Cy5 in an advantageous region with minimal interference from cellular autofluorescence, enhancing signal-to-noise ratios in complex biological samples. Additionally, Cy5's relative stability and resistance to photobleaching compared to other fluorophores in its class make it suitable for extended imaging sessions or applications requiring repeated excitation .

How does Cy5 antibody conjugation chemistry work at the molecular level?

Cy5 antibody conjugation typically utilizes N-hydroxysuccinimide (NHS) ester chemistry to form stable amide bonds with primary amines on the antibody molecule. The reaction primarily targets lysine residues and the N-terminus of the antibody. Modern conjugation kits like the LYNX Rapid Plus Cy5 Antibody Conjugation Kit employ pre-prepared lyophilized mixtures containing the Cy5 label that can react with antibodies under mild conditions .

The reaction occurs optimally at slightly alkaline pH (7.2-8.5), where lysine residues are sufficiently deprotonated to act as nucleophiles but protein stability is maintained. The conjugation process involves:

  • Modification of the antibody with a special reagent that activates primary amines

  • Reaction with the pre-prepared Cy5 dye mixture

  • Quenching of the reaction to terminate any further conjugation

This chemistry allows for controlled labeling with reasonable preservation of antibody function, although overconjugation can potentially impact antigen binding if lysine residues within or near the antigen-binding site become modified .

What factors influence the degree of labeling (DOL) in Cy5-antibody conjugates?

The degree of labeling (DOL), representing the average number of Cy5 molecules attached per antibody molecule, is influenced by several experimental parameters:

ParameterEffect on DOLOptimization Strategy
Reaction pHHigher pH increases conjugation efficiencyMaintain pH 8.0-8.5 for optimal balance
Antibody concentrationHigher concentration may increase conjugation efficiencyTypically 1-4 mg/mL is recommended
Molar ratio of dye to antibodyHigher ratios increase DOLBalance between sufficient labeling and antibody function
Reaction timeLonger time increases DOLMonitor to prevent overconjugation
Reaction temperatureHigher temperatures increase reaction rateAmbient temperature (20-25°C) typically used

The optimal DOL depends on the specific application, with values typically ranging from 2-6 Cy5 molecules per antibody for most immunoassays. Excessive labeling can lead to fluorescence quenching and reduced antibody functionality, while insufficient labeling results in weak signal intensity. Finding the appropriate balance is essential for experimental success .

How should Cy5-conjugated antibodies be stored to maintain optimal activity?

Proper storage of Cy5-conjugated antibodies is critical for maintaining their fluorescence and binding properties. Based on established protocols, Cy5-conjugated antibodies should be stored at 2-8°C in the dark, as exposure to light can lead to photobleaching of the fluorophore. Freezing should generally be avoided as freeze-thaw cycles can cause protein denaturation and aggregation, potentially compromising antibody function .

For storage buffer composition, phosphate-buffered saline (PBS) containing a small amount of sodium azide (<0.1%) and protein stabilizers (e.g., BSA or other carrier proteins) is typically recommended. The stabilizer helps prevent adsorption of the antibody to container surfaces and offers protection against denaturation .

Long-term stability data indicates that properly stored Cy5 conjugates typically maintain >80% of their original activity for at least 12 months under refrigerated conditions. For critical applications, aliquoting the conjugated antibody into single-use volumes can prevent contamination and reduce the impact of repeated freeze-thaw cycles when freezing cannot be avoided .

What are the optimal sample preparation methods for reducing autofluorescence when using Cy5-labeled antibodies?

Autofluorescence can significantly impact the signal-to-noise ratio when working with Cy5-labeled antibodies, particularly in tissue samples or certain cell types. Effective sample preparation techniques include:

  • Chemical treatments:

    • Sodium borohydride (NaBH₄) treatment (1 mg/mL for 10 minutes) to reduce aldehyde-induced autofluorescence

    • Sudan Black B (0.1-0.3% in 70% ethanol) to mask lipofuscin-derived autofluorescence

  • Photobleaching:

    • Pre-exposure of samples to light in the autofluorescence excitation range without the Cy5 filter

  • Buffer optimization:

    • Inclusion of copper sulfate (5 mM) to quench porphyrin-based autofluorescence

    • Addition of Tris (10-50 mM) to the mounting medium

  • Optical approaches:

    • Utilization of spectral unmixing during image acquisition

    • Implementation of time-gated detection to exploit Cy5's longer fluorescence lifetime

These methods can be combined as needed based on the specific sample type and imaging requirements. For particularly challenging samples, conducting a preliminary autofluorescence assessment using unstained controls is recommended to identify the most appropriate mitigation strategy .

How do different fixation methods affect Cy5 antibody staining in immunofluorescence applications?

The choice of fixation method significantly impacts Cy5 antibody staining outcomes in immunofluorescence applications. Various fixatives interact differently with cellular structures and can affect epitope accessibility and Cy5 fluorescence:

Fixation MethodEffect on Cy5 SignalEpitope PreservationRecommended Applications
4% ParaformaldehydeModerate to strong signal, good morphologyGood for most epitopesGeneral IF applications, particularly for membrane proteins
MethanolMay enhance Cy5 signal for certain intracellular targetsBetter for structural proteins, may destroy some conformational epitopesNuclear proteins, cytoskeletal elements
AcetoneQuick fixation, good signal intensityPoor morphology preservationQuick studies where fine structure is less important
GlutaraldehydeCan cause autofluorescence in the green channel but less effect on Cy5Excellent ultrastructural preservationElectron microscopy correlative studies
GlyoxalReduced autofluorescence, compatible with Cy5Comparable to PFA for many epitopesAlternative to PFA when autofluorescence is problematic

For optimal results with Cy5-conjugated antibodies, a post-fixation quenching step (such as treatment with 50 mM NH₄Cl) is recommended when using aldehyde-based fixatives to reduce background fluorescence. Additionally, optimizing the fixation time is critical—excessive fixation can mask epitopes and reduce antibody binding, while insufficient fixation may compromise structural integrity .

How can researchers address non-specific binding of Cy5-conjugated antibodies in flow cytometry?

Non-specific binding of Cy5-conjugated antibodies represents a common challenge in flow cytometry that can complicate data interpretation. To address this issue, researchers should implement a systematic approach:

  • Blocking optimization:

    • Increase blocking agent concentration (typically 5-10% serum from the same species as the secondary antibody)

    • Extend blocking time to 45-60 minutes at room temperature

    • Consider alternative blocking agents such as commercially available blocking buffers containing irrelevant immunoglobulins

  • Antibody titration:

    • Perform careful titration experiments to determine the optimal concentration that maximizes signal-to-noise ratio

    • Generate titration curves plotting mean fluorescence intensity against antibody concentration

  • Control implementation:

    • Include fluorescence minus one (FMO) controls to establish proper gating strategies

    • Utilize isotype controls matching the primary antibody's isotype with the same fluorophore (e.g., Mouse IgG1-APC/CY5.5 as control for Mouse Anti-Human CD19-APC/CY5.5)

    • Incorporate biological negative controls (cells known not to express the target)

  • Buffer optimization:

    • Add 0.1-0.5% BSA to staining buffers to reduce non-specific binding

    • Include low concentrations (0.01-0.05%) of detergents like Tween-20 to reduce hydrophobic interactions

    • Consider the addition of 10-100 μg/mL of irrelevant immunoglobulin from the same species as the primary antibody

Implementing these strategies has been shown to reduce background fluorescence by up to 85% in challenging samples, significantly improving the reliability of flow cytometry data with Cy5-conjugated antibodies .

What approaches can resolve signal overlap when using Cy5 in multiplex fluorescence assays?

Signal overlap (spectral spillover) presents a significant challenge in multiplex fluorescence assays using Cy5 alongside other fluorophores. Effective resolution of this issue requires both experimental design considerations and data analysis approaches:

  • Panel design strategies:

    • Assign Cy5 to less abundant targets, as its emission spectrum may overlap with other red and far-red fluorophores

    • Maintain adequate spectral separation between fluorophores (minimum 30 nm between emission maxima)

    • Consider brightness hierarchy: assign brighter fluorophores like Cy5 to less abundant targets

  • Instrumentation optimization:

    • Utilize narrow bandpass filters to minimize collection of overlapping emissions

    • Perform regular instrument calibration using single-color controls

    • Consider advanced systems with spectral detectors for improved separation

  • Computational correction methods:

    • Implement mathematical compensation using properly prepared single-stained controls

    • Apply spectral unmixing algorithms for closely overlapping fluorophores

    • Consider advanced analysis approaches such as principal component analysis for complex multiplexed data

  • Alternative approaches:

    • Sequential staining and imaging/analysis when complete spectral separation is not possible

    • Photobleaching of Cy5 after initial data collection before proceeding with potentially overlapping fluorophores

    • Utilization of quantum dots or other fluorophores with narrower emission spectra in place of Cy5 for certain targets

Proper implementation of these approaches has been shown to reduce false positive signals by up to 95% in six-color panels including Cy5, significantly improving data reliability in complex multiplexed assays .

How do photobleaching rates of Cy5 compare to other common fluorophores, and what strategies minimize this effect?

Cy5 exhibits distinct photobleaching characteristics compared to other common fluorophores, which must be considered in experimental design, particularly for applications requiring extended or repeated imaging:

FluorophoreRelative Photobleaching Rate (lower is better)Half-life Under Standard Confocal Imaging
Cy51.0 (reference)~120-180 seconds
Alexa Fluor 6470.6~200-300 seconds
FITC2.5~40-60 seconds
TRITC1.8~60-90 seconds
GFP1.2~100-150 seconds

To minimize photobleaching effects when working with Cy5-labeled antibodies:

  • Illumination optimization:

    • Reduce excitation intensity to the minimum required for adequate signal

    • Minimize exposure time during image acquisition

    • Utilize pulsed illumination rather than continuous excitation

  • Chemical additives:

    • Include anti-fading agents in mounting media (e.g., p-phenylenediamine, DABCO)

    • Add oxygen scavengers such as glucose oxidase/catalase systems

    • Consider commercial anti-fade mountants specifically formulated for cyanine dyes

  • Sample preparation considerations:

    • Maintain samples at lower temperatures during imaging

    • Seal slides completely to prevent oxygen influx

    • Protect samples from ambient light exposure before imaging

  • Computational approaches:

    • Implement denoising algorithms to allow acquisition at lower excitation intensities

    • Use deconvolution to enhance signal from minimally exposed samples

    • Apply photobleaching correction in time-series experiments

Implementation of these strategies can extend the effective imaging time of Cy5-conjugated antibodies by 3-5 fold, enabling more comprehensive data collection before significant signal degradation occurs .

How can Cy5-conjugated antibodies be optimized for super-resolution microscopy techniques?

Optimizing Cy5-conjugated antibodies for super-resolution microscopy requires specific considerations beyond standard immunofluorescence protocols. For techniques such as Stimulated Emission Depletion (STED), Stochastic Optical Reconstruction Microscopy (STORM), and Photoactivated Localization Microscopy (PALM), the following optimizations are critical:

  • Conjugation strategy optimization:

    • Control degree of labeling (DOL) precisely; for STORM/PALM, a higher DOL of 4-8 Cy5 molecules per antibody is often beneficial

    • Consider site-specific conjugation approaches targeting the Fc region to maintain full antigen-binding capacity

    • For some applications, using F(ab) or F(ab')₂ fragments instead of whole antibodies reduces the distance between fluorophore and target

  • Buffer composition for photoswitching:

    • For STORM/PALM: Include thiol-containing buffers (50-100 mM MEA or β-mercaptoethylamine)

    • Incorporate oxygen scavenging systems (glucose oxidase/catalase)

    • Adjust pH to 7.5-8.0 to optimize Cy5 photoswitching kinetics

  • Sample preparation refinements:

    • Reduce fixation time to minimize epitope masking

    • Utilize non-hardening mounting media specific for super-resolution approaches

    • Consider thin tissue sections (≤10 μm) to minimize out-of-focus fluorescence

  • Instrument-specific optimizations:

    • For STED: Balance depletion laser power to maximize resolution while minimizing photobleaching

    • For STORM: Optimize laser power cycling for efficient photoswitching

    • Calibrate system using fiducial markers labeled with Cy5 for drift correction

These optimizations have enabled researchers to achieve lateral resolutions of 20-30 nm using Cy5-conjugated antibodies in super-resolution microscopy, representing a 10-fold improvement over conventional diffraction-limited techniques .

What considerations are important when designing protein microarrays using Cy5-labeled antibodies for quantitative proteomics?

When designing protein microarrays using Cy5-labeled antibodies for quantitative proteomics, several critical parameters must be optimized to ensure reliable and reproducible results:

  • Antibody selection and validation:

    • Prioritize monoclonal antibodies with confirmed specificity via Western blot or ELISA

    • Validate antibody performance after Cy5 labeling to ensure retained specificity

    • Consider epitope availability in the microarray format (native vs. denatured proteins)

  • Surface chemistry optimization:

    • Select appropriate slide surface chemistry (e.g., epoxy, aldehyde, nitrocellulose) based on protein characteristics

    • Implement rigorous blocking protocols to minimize non-specific binding

    • Consider three-dimensional hydrogel coatings for improved protein functionality

  • Experimental design for quantification:

    • Implement two-color approaches using Cy3/Cy5 for comparative analysis

    • Include calibration curves with known concentrations of purified proteins

    • Incorporate multiple technical replicates (6-12 spots per antibody) to assess reproducibility

  • Data analysis considerations:

    • Apply appropriate normalization methods to account for spot-to-spot variation

    • Utilize log-transformed ratios (log₁₀(R/G)) for more accurate concentration representation

    • Implement statistical approaches that account for the non-normal distribution of fluorescence data

Research has demonstrated that properly optimized Cy5-based protein microarrays can achieve detection limits of approximately 5 ng/ml for many proteins, with quantitative accuracy (within twofold of actual concentration) achievable for approximately 50% of antibody-antigen pairs at concentrations above 100 ng/ml . The detection efficiency varies significantly based on antibody affinity and the nature of the target protein.

How do different conjugation methods affect the functionality of Cy5-antibody conjugates in multiplexed immunoassays?

The conjugation method used to attach Cy5 to antibodies significantly impacts the resulting conjugate's performance in multiplexed immunoassays. Understanding these differences is crucial for optimizing assay sensitivity, specificity, and reproducibility:

Conjugation MethodImpact on Antibody FunctionSignal IntensityBatch-to-Batch VariabilityBest Applications
NHS ester chemistry (random labeling)Moderate impact; potential binding interferenceHighModerate to highGeneral purpose applications
Maleimide chemistry (thiol-directed)Minimal impact on binding sitesModerate to highLow to moderateApplications requiring preserved binding affinity
Click chemistry (bio-orthogonal)Minimal impact on antibody structureModerateVery lowHighly sensitive assays requiring reproducibility
Site-specific enzymatic approachesPreserved antibody orientation and functionModerateLowComplex multiplexed assays
Protein A/G-directed labelingFc-specific labeling preserves antigen bindingHighLow to moderateFlow cytometry, imaging applications

Research comparing these methods has demonstrated that:

  • NHS ester chemistry (as used in the LYNX Rapid Plus Cy5 Antibody Conjugation Kit) provides high signal intensity but can result in heterogeneous labeling with DOL variations between 2-8 Cy5 molecules per antibody . This approach is efficient but may compromise binding affinity for approximately 15-20% of antibodies.

  • Site-specific conjugation approaches targeting the Fc region can preserve antigen binding capacity more effectively, with studies showing up to 95% retention of antigen binding compared to 70-85% for random labeling methods.

  • Enzymatic approaches using transglutaminase or sortase-mediated conjugation provide exceptional consistency but may require genetic modification of antibodies or specialized reagents.

For multiplexed immunoassays specifically, site-specific conjugation methods typically provide superior results due to their consistent DOL and preserved antibody orientation, particularly important when detecting low-abundance targets in complex samples .

How are Cy5-antibody conjugates being utilized in multi-parameter flow cytometry panels for immune cell phenotyping?

Cy5-antibody conjugates, particularly in tandem formats like APC/Cy5.5, have become instrumental in developing high-dimensional flow cytometry panels for comprehensive immune cell phenotyping. Current research applications demonstrate several key aspects of their utilization:

  • Panel design strategies:

    • APC/Cy5.5-conjugated antibodies targeting moderately expressed antigens like CD19 are positioned strategically in panels to maximize resolution

    • Compensation matrices incorporate the specific spectral characteristics of Cy5 tandems to minimize spillover

    • Titration of Cy5-conjugated antibodies is performed individually within the context of the full panel to account for fluorescence interactions

  • Clinical research applications:

    • Monitoring B cell populations in end-stage renal disease patients, where specific staining of CD19 with APC/Cy5.5 conjugates has revealed altered B cell subset distributions

    • Evaluation of immature B cell populations in transplant recipients during the early post-transplantation period

    • Assessment of B cell-associated immune profiles in various immunological disorders

  • Technical advantages in multi-parameter applications:

    • APC/Cy5.5 conjugates provide excellent separation from other fluorochromes in the red and far-red spectrum

    • Stability of the tandem dye configuration allows for consistent performance in cryopreserved samples

    • Modern instrumentation with spectral flow cytometry capabilities further enhances the utility of Cy5-based conjugates

Studies have demonstrated the successful integration of APC/Cy5.5 anti-CD19 antibodies in panels containing 10+ parameters, enabling detailed characterization of B cell subsets based on additional markers including CD27, IgD, CD24, and CD38 . This approach has been validated in multiple clinical research settings, indicating robust performance across different sample types and experimental conditions.

What role do Cy5-conjugated antibodies play in quantitative protein microarray technology for biomarker discovery?

Cy5-conjugated antibodies have become essential tools in quantitative protein microarray technology for biomarker discovery, offering several distinct advantages for high-throughput proteomics research:

  • Comparative fluorescence assay applications:

    • Implementation of two-color approaches using Cy3 (green) as a reference and Cy5 (red) for experimental samples enables precise relative quantitation

    • Visualization of concentration-dependent color changes from red (high concentration) to yellow (equal concentration) to green (low concentration) provides intuitive data interpretation

    • Log₁₀ transformations of red-to-green ratios (log₁₀(R/G)) deliver reliable quantitative measurements across concentration ranges spanning several orders of magnitude

  • Performance characteristics in microarray formats:

    • Detection sensitivity for many antigens reaches approximately 5 ng/ml using Cy5-labeled antibodies

    • Quantitative accuracy (within twofold of actual concentration) is achievable for approximately 50% of antibodies at concentrations above 100 ng/ml

    • Antigen microarrays generally outperform antibody microarrays in terms of detection sensitivity and quantitative accuracy

  • Technical considerations for biomarker discovery:

    • Differential protein labeling with Cy5 must account for variable labeling efficiency across diverse protein structures

    • Normalization strategies are essential to account for potential labeling biases

    • Statistical analysis must incorporate technical variation introduced by the labeling process

Research has demonstrated that Cy5-based protein microarrays can successfully identify and quantify multiple proteins simultaneously in complex biological samples, with applications in cancer biomarker discovery, autoimmune disease profiling, and pharmaceutical development . The methodology continues to evolve with improvements in surface chemistry, detection sensitivity, and data analysis algorithms.

How can researchers optimize Cy5-antibody conjugates for in vivo optical imaging applications?

The application of Cy5-antibody conjugates in in vivo optical imaging presents unique challenges requiring specific optimizations to achieve meaningful biological insights:

  • Pharmacokinetic considerations:

    • Optimize degree of labeling (DOL) to balance signal intensity with antibody circulation time

    • Consider antibody fragments (Fab, F(ab')₂, nanobodies) to improve tissue penetration and reduce background

    • Evaluate albumin binding of Cy5 conjugates, which can alter biodistribution profiles

  • Signal optimization strategies:

    • Implement activatable Cy5 conjugates that increase fluorescence upon target binding

    • Consider pH-sensitive Cy5 variants that enhance signal in specific microenvironments

    • Utilize paired-agent imaging approaches with control antibodies to account for non-specific accumulation

  • Instrumentation and acquisition parameters:

    • Select appropriate excitation sources and emission filters optimized for Cy5's spectral properties

    • Implement time-domain imaging to leverage Cy5's fluorescence lifetime

    • Consider photoacoustic imaging approaches to increase tissue penetration depth

  • Biological considerations:

    • Account for autofluorescence from diet (implement alfalfa-free diets)

    • Consider fur removal or utilize animals with reduced pigmentation

    • Optimize imaging windows based on antibody pharmacokinetics

Research has demonstrated successful application of Cy5-antibody conjugates for in vivo imaging of various targets, with optimal imaging typically occurring 24-72 hours post-injection for full antibodies and 4-24 hours for antibody fragments. The approach allows for multiplexed imaging when combined with fluorophores in other spectral regions, enabling simultaneous visualization of multiple biological processes.

Quick Inquiry

Personal Email Detected
Please use an institutional or corporate email address for inquiries. Personal email accounts ( such as Gmail, Yahoo, and Outlook) are not accepted. *
© Copyright 2025 TheBiotek. All Rights Reserved.