GCLM Antibody

Shipped with Ice Packs
In Stock

Product Specs

Buffer
The antibody is supplied in a liquid form, dissolved in PBS buffer containing 50% glycerol, 0.5% bovine serum albumin (BSA), and 0.02% sodium azide.
Form
Liquid
Lead Time
We typically ship orders within 1-3 business days of receipt. Delivery times may vary depending on the shipping method and destination. For specific delivery timelines, please contact your local distributor.
Synonyms
Gamma ECS regulatory subunit antibody; Gamma-ECS regulatory subunit antibody; Gamma-glutamylcysteine synthetase regulatory subunit antibody; GCLM antibody; GCS light chain antibody; GLCLR antibody; Glutamate cysteine ligase regulatory subunit antibody; Glutamate--cysteine ligase modifier subunit antibody; Glutamate--cysteine ligase regulatory subunit antibody; GSC light chain antibody; GSH0_HUMAN antibody
Target Names
GCLM
Uniprot No.

Customer Reviews

Overall Rating 5.0 Out Of 5
,
B.A
By Anonymous
★★★★★

Applications : Western blot assays

Sample type: Human cells

Review: In parallel, the effects of SHQA were also observed for Nrf2-driven expression of antioxidant/phase II detoxifying enzymes, including HO-1, NQO1, GCLc, GCLm, and TrxR. In particular, HO-1 expression significantly increased after pretreatment with SHQA at 0.1 µM.

Q&A

Which applications are most suitable for GCLM antibody detection?

GCLM antibodies have been validated for multiple research applications, with varying degrees of effectiveness depending on the specific antibody. The most common applications include:

ApplicationValidated SuccessTypical Dilution Ranges
Western Blot (WB)Extensively validated with 138+ publications1:500-1:10000
Immunohistochemistry (IHC)Validated in various tissues1:400-1:1600
Immunofluorescence (IF/ICC)Validated in cell lines1:50-1:500
Immunoprecipitation (IP)Validated in certain cell lines0.5-4.0 μg for 1.0-3.0 mg protein
Flow Cytometry (FC)Validated for intracellular staining0.25 μg per 10^6 cells

The choice of application should be guided by your experimental question, with Western blot being the most widely validated method for GCLM detection .

How should I choose between monoclonal and polyclonal GCLM antibodies?

The choice between monoclonal and polyclonal GCLM antibodies depends on your specific research needs:

Monoclonal antibodies (like mouse anti-human monoclonal P2D12AT) offer high specificity to a single epitope, providing excellent reproducibility and reduced background . They are ideal for applications requiring consistent results across multiple experiments or for distinguishing between closely related proteins.

Polyclonal antibodies (like the rabbit polyclonal 14241-1-AP) recognize multiple epitopes on GCLM, potentially offering higher sensitivity, especially in applications where protein conformation might be altered (e.g., fixed tissues in IHC) . They can be advantageous when protein expression is low.

For quantitative applications like Western blot, either type can work well, though monoclonals may provide more consistent results. For applications like IHC where antigen retrieval might affect epitope accessibility, polyclonal antibodies might offer better detection capabilities .

How can I optimize Western blot protocols specifically for GCLM detection?

Optimizing Western blot for GCLM (31 kDa) detection requires attention to several key parameters:

Sample preparation: To detect both GCLM individually and its association with GCLC, prepare samples under both reducing and non-reducing conditions. For reducing conditions, mix protein samples with loading buffer containing 80 mM DTT and heat at 95°C for 4 minutes. For non-reducing conditions, load protein without DTT treatment or heating to preserve protein-protein interactions .

Gel percentage: Use 10-12% SDS-PAGE gels for optimal separation of the 31 kDa GCLM protein. For holoenzyme detection, 7.5% gels provide better resolution of higher molecular weight complexes .

Antibody dilution titration: Start with the recommended range (1:2000-1:10000 for most GCLM antibodies), but perform a titration with your specific sample type. Using purified GCLM protein as a standard curve on each gel allows for accurate quantification .

Detection system: HRP-conjugated anti-rabbit or anti-mouse IgG antibodies (depending on your primary antibody host) work well for GCLM detection .

Positive controls: Include HepG2, A431, or HeLa cell lysates as positive controls, as they consistently show GCLM expression .

What approaches can detect GCLM-GCLC interactions and holoenzyme formation?

To study GCLM-GCLC interactions and holoenzyme formation, several complementary approaches are recommended:

Native PAGE analysis: Run protein samples under non-reducing conditions without DTT or heat treatment on 7.5% gels. This preserves protein-protein interactions and allows visualization of the intact GCL holoenzyme .

Co-immunoprecipitation: Use GCLM antibodies (0.5-4.0 μg per 1.0-3.0 mg of protein lysate) to pull down the protein complex, then probe with anti-GCLC antibodies in subsequent Western blots to confirm interaction .

Proximity ligation assays: This technique can visualize protein-protein interactions in situ with high sensitivity, though it requires antibodies raised in different host species.

Differential quantification: Compare the amount of GCLM detected under reducing versus non-reducing conditions. A shift in molecular weight under non-reducing conditions suggests holoenzyme formation or other protein interactions .

When interpreting results, consider that the association between GCLM and GCLC can be dynamic and respond to cellular stress conditions, particularly oxidative stress .

How can I accurately measure GCL activity in conjunction with GCLM detection?

To correlate GCLM expression with GCL enzymatic activity:

Enzyme activity assay: Measure GCL activity under conditions approaching Vmax using 50 mM L-glutamate and 5 mM L-cysteine as substrates. Quantify γ-glutamylcysteine production using HPLC according to established methods .

Western blot correlation: In parallel samples, quantify GCLM and GCLC protein levels by Western blotting. Generate standard curves using purified proteins for accurate quantification .

mRNA expression analysis: Perform Northern blot or qRT-PCR analysis of GCLM mRNA using cDNA probes or primers corresponding to specific regions of the GCLM sequence to correlate transcriptional regulation with protein expression and enzyme activity .

Glutathione measurement: Assess total glutathione levels (GSH and GSSG forms) using established HPLC methods to correlate with GCL activity. This provides a functional readout of the pathway's end product .

This multi-parameter approach allows you to determine whether changes in GCL activity correlate with alterations in GCLM expression, GCLM-GCLC association, or post-translational modifications.

What are common sources of non-specific binding with GCLM antibodies and how can they be minimized?

Non-specific binding can confound GCLM antibody experiments. Common issues and solutions include:

Background in Western blots:

  • Increase blocking time (5% non-fat milk or BSA in TBST for at least 1 hour)

  • Use more stringent washing (increase TBST wash steps to 3-5 times, 10 minutes each)

  • Titrate antibody to lower concentrations (start at 1:10000 for WB applications)

  • Include reducing agents in sample buffer to minimize potential aggregate formation

IHC/IF background issues:

  • Optimize antigen retrieval conditions (GCLM antibodies often work best with TE buffer pH 9.0, though citrate buffer pH 6.0 is an alternative)

  • Use shorter primary antibody incubation times at higher dilutions (1:1000-1:1600)

  • Include 0.1-0.3% Triton X-100 in antibody diluent to reduce non-specific membrane interactions

  • Pre-adsorb antibodies with acetone powder from non-relevant tissues

Validation strategies:

  • Include GCLM-knockout or GCLM-knockdown samples as negative controls

  • Check antibody specificity via immunoprecipitation followed by mass spectrometry

  • Verify results with a second antibody targeting a different epitope of GCLM

How should I adjust GCLM antibody protocols when working with different species samples?

GCLM antibodies show variable cross-reactivity across species. When adapting protocols for different species:

Species reactivity verification:

  • Most commercial GCLM antibodies are validated in human, mouse, and rat samples

  • Goat reactivity has been cited but may require additional validation

  • For non-validated species, perform a preliminary Western blot with positive controls

Species-specific optimizations:

  • For mouse/rat tissues, especially liver samples, reduce primary antibody concentration by 25-50% compared to human samples due to typically higher GCLM expression

  • For non-human primate samples, human-optimized protocols usually work well with minimal adjustments

  • For other species, begin with conservative antibody dilutions (1:500 for WB, 1:50 for IF) and optimize from there

Antigen retrieval adjustments:

  • Rodent tissues may require more aggressive antigen retrieval (increase time by 25%)

  • For fixed tissues from different species, comparative testing of TE buffer pH 9.0 versus citrate buffer pH 6.0 is recommended

How can GCLM antibodies be used to study oxidative stress responses?

GCLM antibodies are valuable tools for investigating oxidative stress mechanisms:

ROS-induced GCLM regulation:

  • Combine GCLM protein detection with DCF fluorescence assays to correlate ROS levels with GCLM expression changes

  • Use time-course experiments after oxidative stress induction to track GCLM upregulation kinetics

  • Compare GCLM and GCLC expression patterns under stress to identify differential regulation

Methodology integration:

  • Measure intracellular ROS using DCFH-DA (10 μM in PBS, 30 min incubation at 37°C)

  • Quantify lipid peroxidation via TBARS assay using tetraethoxypropane as standard

  • Perform Western blot for GCLM protein levels

  • Measure glutathione levels via HPLC using S-carboxymethyl derivatives

  • Correlate all parameters to establish mechanism of action

This integrated approach allows researchers to establish causative relationships between oxidative stress, GCLM expression changes, and subsequent alterations in glutathione synthesis capacity.

What approaches enable studying GCLM post-translational modifications?

Post-translational modifications of GCLM can significantly affect its function and interactions:

Recommended methodologies:

  • Perform immunoprecipitation using GCLM antibodies (0.5-4.0 μg for 1-3 mg of protein lysate)

  • Follow with mass spectrometry analysis to identify PTMs

  • Use phospho-specific antibodies (when available) for Western blot after membrane stripping

  • Compare reducing vs. non-reducing conditions to identify disulfide-dependent modifications

2D gel electrophoresis approach:

  • Separate proteins by isoelectric point in the first dimension

  • Follow with SDS-PAGE separation in the second dimension

  • Perform Western blot with GCLM antibodies

  • Multiple spots at the expected molecular weight suggest post-translational modifications

For specific oxidative modifications, specialized techniques like OxyBlot can be combined with GCLM immunoprecipitation to assess oxidation status under different experimental conditions.

How can GCLM antibodies be applied in mass cytometry and advanced imaging techniques?

GCLM antibodies are increasingly being used in advanced imaging technologies:

Mass cytometry (CyTOF):

  • CPTC-GCLM-1 antibody has been validated for imaging mass cytometry on lung cancer tissue cores and multiple normal and cancer tissues

  • Typical dilution is 1:100 of 0.5mg/mL stock for tissue analysis

  • Signal can be successfully obtained across diverse tissue types including prostate, colon, pancreas, breast, lung, testis, endometrium, appendix, and kidney tissues

Advanced imaging approaches:

  • Super-resolution microscopy can be performed using directly-labeled GCLM antibodies

  • For correlative light-electron microscopy, immunogold labeling with GCLM antibodies allows ultrastructural localization

  • Multiplex immunofluorescence with GCLM antibodies allows co-localization studies with other proteins in the glutathione synthesis pathway

These advanced applications require high-quality antibodies with minimal non-specific binding and careful optimization of dilution factors for each specific technique.

What considerations are important when designing GCLM knockdown/knockout validation experiments?

Validation of GCLM antibody specificity through genetic manipulation approaches:

siRNA/shRNA knockdown validation:

  • Target multiple regions of GCLM mRNA for most effective knockdown

  • Include non-targeting control siRNAs to account for off-target effects

  • Verify knockdown efficiency at both mRNA (qRT-PCR) and protein (Western blot) levels

  • Use at least a 72-hour time point for complete protein depletion assessment

CRISPR/Cas9 knockout validation:

  • Design guide RNAs targeting early exons of GCLM

  • Screen clones by genomic PCR and sequencing to confirm mutations

  • Verify complete protein loss by Western blot with GCLM antibodies

  • Include functional assays (glutathione levels, ROS sensitivity) to confirm biological impact

Complementation studies:

  • Re-express GCLM in knockout cells to confirm specificity of observed phenotypes

  • Use tagged versions (e.g., FLAG-GCLM) to distinguish endogenous from exogenous protein

  • Consider expressing the GCLM mutant variants to investigate structure-function relationships

Knockout/knockdown validation provides the most stringent control for antibody specificity and has been successfully employed in at least one published GCLM study .

Quick Inquiry

Personal Email Detected
Please use an institutional or corporate email address for inquiries. Personal email accounts ( such as Gmail, Yahoo, and Outlook) are not accepted. *
© Copyright 2025 TheBiotek. All Rights Reserved.