ifa-3 Antibody

Shipped with Ice Packs
In Stock

Description

Potential Terminology Clarification

The term "ifa-3" may represent one of the following:

  • Typographical variation: A misspelling or formatting error for IRF-3 (Interferon Regulatory Factor 3), a well-characterized transcription factor in innate immunity .

  • Assay-specific nomenclature: A reference to antibodies used in Indirect Immunofluorescence Assays (IFA), such as those targeting nuclear antigens (e.g., ANNA3) or cytoplasmic proteins (e.g., PR3-ANCA) .

  • Commercial product code: A proprietary designation for antibodies like IRF-3 (D9J5Q) Mouse mAb #10949 , though no "ifa-3" labeling exists in the provided sources.

Key Antibodies Associated with IFA Testing

While "ifa-3 Antibody" remains unidentified, prominent antibodies validated for IFA applications include:

Table 1: Antibodies with IFA Utility in Research and Diagnostics

Target AntigenAntibody ClassApplications (IFA)Key FunctionsSource
IRF-3Mouse monoclonal (#10949)Immunohistochemistry, ImmunofluorescenceRegulates innate immune response genes; phosphorylated during viral infection Cell Signaling Technology
PR3-ANCAIgG/IgA/IgMAutoimmune vasculitis diagnosticsBinds proteinase 3 on neutrophils, triggering inflammation MDPI, Frontiers in Immunology
ANNA3IgG (anti-DACH1)Paraneoplastic syndrome diagnosticsTargets Dachshund homolog 1 (DACH1) in neuronal nuclei PMC
DFS70/LEDGFp75IgGExclusion of ANA-associated rheumatic diseasesProduces dense fine speckled nuclear pattern PMC

Research Findings on IRF-3 Antibodies (Closest Conceptual Match)

The IRF-3 (D9J5Q) Mouse mAb #10949 is extensively characterized:

  • Specificity: Detects endogenous IRF-3 at 50–55 kDa in human samples.

  • Functional Role:

    • Phosphorylated at Ser396 during viral infection, enabling nuclear translocation and activation of interferon-stimulated genes .

    • Critical for TLR3/4-mediated immune responses via TBK1/IKKε signaling .

  • Applications:

    • Immunohistochemistry (1:400 dilution in paraffin-embedded tissues).

    • Immunofluorescence (1:400 dilution for subcellular localization studies) .

Methodological Insights from IFA Studies

IFA protocols for antibody detection emphasize:

  • Sensitivity/Specificity Metrics:

    • Yellow Fever Virus (YFV) IgG/IgM IFA: 95% sensitivity and 95% specificity vs. PRNT .

    • PR3-ANCA IFA: 34.9% sensitivity for discriminating ulcerative colitis from Crohn’s disease .

  • Technical Limitations:

    • Cross-reactivity with heterologous flavivirus antibodies (e.g., dengue, West Nile virus) .

    • False negatives in preimmune sera with low-titer neutralizing antibodies .

Product Specs

Buffer
Preservative: 0.03% Proclin 300
Constituents: 50% Glycerol, 0.01M Phosphate Buffered Saline (PBS), pH 7.4
Form
Liquid
Lead Time
Made-to-order (14-16 weeks)
Synonyms
ifa-3 antibody; F52E10.5Intermediate filament protein ifa-3 antibody; Cel IF A3 antibody; Intermediate filament protein A3 antibody; IF-A3 antibody
Target Names
ifa-3
Uniprot No.

Target Background

Function
Cytoplasmic intermediate filaments play a crucial role in providing mechanical strength to cells. This essential protein is involved in the attachment structures within epidermal cells, connecting muscles to the external cuticle. It is required for epidermal morphogenesis during embryonic development. Furthermore, it is a probable component of embryonic epidermal attachment structures.
Database Links

KEGG: cel:CELE_F52E10.5

STRING: 6239.F52E10.5

UniGene: Cel.7442

Protein Families
Intermediate filament family
Subcellular Location
Cytoplasm.
Tissue Specificity
Expressed in the embryonic and larval hypodermis. Also expressed in the ventral nerve cord of larvae.

Q&A

What is the basic principle behind Indirect Fluorescent Antibody (IFA) assays?

IFA is an assay that uses fluorescent microscopy to detect antibodies to specific antigenic material. The fundamental principle involves a two-step immunological process: first, primary antibodies in the test sample bind to fixed antigens (typically in cells), and second, fluorescent dye-conjugated secondary antibodies (anti-immunoglobulins) bind to these primary antibodies. When examined under a fluorescence microscope, bright granular fluorescence indicates a specific antibody-antigen reaction. This visualization capability makes IFA particularly valuable as a confirmation test, as it allows researchers to observe the precise location of antibody-antigen reactions within infected cells .

How does IFA differ from other antibody detection methods like ELISA and RIA?

IFA differs from other antibody detection methods in several key aspects:

  • Visualization: Unlike ELISA or RIA, IFA provides visual confirmation of antibody-antigen binding locations within cells.

  • Methodology: While ELISA uses enzymatic reactions in microplate wells and RIA employs radioactive labels, IFA utilizes fluorescent dyes visualized through microscopy .

  • Application scope: IFA is often used as a confirmatory test after initial screening with ELISA or MFIA® (Multiplexed Fluorometric ImmunoAssay®) .

  • Sample preparation: IFA requires cells fixed on microscope slides rather than soluble antigens used in ELISA.

  • Safety considerations: Unlike RIA, IFA doesn't involve handling radioactive materials, which offers advantages in laboratory safety and waste disposal .

Comparative studies show that newer non-radioactive methods like f-CBA-IFA can perform comparably to radioimmunoassay (RIA) for specific applications, with excellent agreement observed between these methods .

What are the core components needed to perform an IFA assay?

The core components required for performing an IFA assay include:

  • Substrate: Typically fixed cells (infected and uninfected control cells) on glass microscope slides. Cold acetone is commonly used as a fixative to permeabilize cell membranes, making intracellular antigens more accessible to antibodies .

  • Test samples: Diluted serum samples containing potential antibodies of interest .

  • Fluorescent conjugate: Anti-immunoglobulin antibodies conjugated to fluorescent dyes that bind to primary antibodies .

  • Fluorescence microscope: Essential for visualizing the fluorescent signals. The microscope must have appropriate excitation and emission filter sets compatible with the fluorophores used .

  • Washing buffers: To remove unbound antibodies and reduce background .

  • Mounting medium: Buffered glycerol is commonly used to prepare slides for microscopic examination .

  • Controls: Positive and negative controls are essential for validating assay performance .

What is the step-by-step protocol for performing an IFA assay?

The standard protocol for performing an IFA assay involves the following steps:

  • Substrate preparation: Infected cells (containing the antigen of interest) and uninfected cells (as controls) are fixed to wells on a glass microscope slide, typically using cold acetone as a fixative. This permeabilizes the cell membrane, making intracellular antigens accessible .

  • Sample application: Diluted serum samples are added to individual slide wells and incubated. During this incubation, antibodies specific to the antigen presented by the infected cells will bind to those antigens .

  • Primary washing: Unbound antibodies are removed by thorough washing .

  • Secondary antibody application: A fluorescent dye-conjugated anti-immunoglobulin is added to reveal the binding of primary antibodies to the infected cells .

  • Secondary washing: Unbound conjugate is removed via washing to reduce background fluorescence .

  • Mounting: Slides are covered with buffered glycerol and a coverslip .

  • Microscopic examination: Slides are examined with a fluorescence microscope. Bright, granular fluorescence is typical of a specific antibody-viral antigen reaction .

This method allows researchers to visually confirm the presence of specific antibodies and observe their binding patterns within cells.

How should I select appropriate fluorophores for IFA experiments?

Selecting appropriate fluorophores for IFA experiments requires consideration of several factors:

  • Microscope configuration: The primary consideration should be the optical configuration of your fluorescence microscope. Check the available excitation light sources (arc lamps or lasers) and filter sets to ensure compatibility with your chosen fluorophores .

  • Multiplexing requirements: If examining multiple targets simultaneously, select fluorophores with minimal spectral overlap to avoid bleed-through between channels. Common combinations include:

    • UV channel (340-370nm excitation/460nm emission): DAPI or Hoechst for nuclear staining

    • Green channel (488nm/520nm): FITC or other 488-compatible dyes

    • Yellow-orange-red (550-575nm/605nm): TRITC or Cy3

    • Far red (640-650nm/670nm): APC, Cy5, or various 647 dyes

  • Target abundance: Consider using brighter fluorophores for low-abundance targets and standard fluorophores for highly expressed targets.

  • Photobleaching properties: Some fluorophores are more resistant to photobleaching, which is important for extended imaging sessions or samples that will be archived.

When planning multiplex experiments, create a table documenting your microscope's specifications and the spectral properties of potential fluorophores to optimize your experimental design .

What controls are essential for validating IFA results?

To ensure the reliability of IFA results, several controls are essential:

  • Omit Primary Antibody Control: A sample processed without the primary antibody but with all other reagents demonstrates whether any observed signal is due to nonspecific binding of the fluorescent secondary antibody to the sample .

  • Isotype Control: Particularly important for direct staining with conjugated primary antibodies. An isotype control (same class and immunoglobulin type as the test antibody but with no specificity for any known epitope) helps ensure that observed signals are due to specific antigen binding rather than nonspecific "stickiness" of the antibody protein .

  • Negative Cell Controls: Cells known not to express the target antigen or genetically modified knockout cells provide a robust control for antibody specificity .

  • Positive Cell Controls: Cells known to express the antigen of interest, either endogenously or through genetic modification, confirm that the staining protocol produces signal when the target is present .

  • Serum Controls: For diagnostic applications, known positive and negative sera should be included to validate assay performance .

Implementing these controls helps distinguish true positive signals from artifacts, enhancing confidence in experimental results and allowing proper interpretation of fluorescence patterns.

How is IFA used in the diagnosis of autoimmune diseases?

IFA plays a crucial role in the diagnosis of autoimmune diseases, particularly in detecting antinuclear antibodies (ANA):

  • Primary screening: IFA using HEp-2 cells (HEp-2 IFA) is the standard method for ANA detection, essential for diagnosing various autoimmune conditions including systemic lupus erythematosus, Sjögren's syndrome, and systemic sclerosis .

  • Pattern recognition: Different autoimmune conditions produce characteristic fluorescence patterns that aid in diagnosis. International consensus on ANA patterns (ICAP) has standardized the classification of these patterns .

  • Titer determination: Serial dilutions of patient sera are tested to determine antibody titers, which can correlate with disease activity or severity in some conditions .

  • Confirmation testing: IFA can confirm positive results from solid phase assays, providing visual evidence of antibody-antigen interactions .

International recommendations emphasize that HEp-2 IFA remains the gold standard for ANA testing despite the availability of alternative methods. Standardization efforts by groups like the European Autoimmune Standardization Initiative (EASI) and International Consensus on ANA Patterns (ICAP) have established guidelines to ensure high-quality testing protocols and consistent interpretation of results .

What factors can affect the sensitivity and specificity of IFA assays?

Multiple factors can influence the sensitivity and specificity of IFA assays:

  • Substrate quality: Variations in cell line characteristics, fixation methods, and manufacturing processes can significantly impact results. Standardized substrates are crucial for consistent performance .

  • Serum dilution: The screening dilution used significantly affects results. Higher dilutions increase specificity but may reduce sensitivity. For ANA testing, a screening dilution of 1:80 is often recommended as a balance between sensitivity and specificity .

  • Microscope components: The quality of the fluorescence microscope, including light source intensity, objective magnification, and filter sets, can impact the detection of weak positive samples .

  • Conjugate selection: The type, quality, and dilution of the fluorescent conjugate affect signal intensity and background levels .

  • Observer expertise: Visual reading of IFA slides is subjective and depends on the interpreter's experience and training. This introduces potential inter-observer variability .

  • Pre-existing immunity: In infectious disease testing, pre-existing antibodies to related pathogens can affect results. For example, studies on yellow fever virus (YFV) IFA showed that individuals with previous flaviviral exposure who received the YFV vaccine often failed to produce detectable IgM antibodies, though they still developed protective immunity .

Evaluations of commercial IFA kits have shown sensitivity and specificity rates typically exceeding 94-95% when validated against gold standard methods .

How should IFA results be reported and interpreted?

Proper reporting and interpretation of IFA results require standardized approaches:

When using automated computer-assisted diagnosis (CAD) systems, laboratories should validate these systems against traditional visual reading and establish clear protocols for handling discrepancies .

What are common sources of false positives and false negatives in IFA, and how can they be mitigated?

Common sources of errors in IFA testing and their mitigation strategies include:

Sources of false positives:

  • Cross-reactivity: Antibodies can recognize similar epitopes on unrelated antigens. This is particularly problematic in infectious disease testing, where antibodies against related pathogens may cross-react. For example, pre-existing immunity to flaviviruses can cause cross-reactivity in yellow fever virus IFA .
    Mitigation: Include absorption steps with related antigens or use more specific confirmatory tests.

  • Nonspecific binding: Certain serum components can bind nonspecifically to the substrate.
    Mitigation: Use proper blocking agents, optimize serum dilutions, and include appropriate controls like isotype controls .

  • Inadequate washing: Insufficient washing can leave unbound antibodies that contribute to background fluorescence.
    Mitigation: Adhere to standardized washing protocols with appropriate buffer systems .

Sources of false negatives:

  • Prozone effect: Very high antibody concentrations can paradoxically lead to negative results.
    Mitigation: Test multiple dilutions of positive samples.

  • Insensitive detection systems: Suboptimal fluorescent conjugates or microscope settings.
    Mitigation: Validate detection systems with known positive samples and standardize microscope settings .

  • Pre-analytical factors: Improper sample handling, storage, or heat inactivation can denature antibodies.
    Mitigation: Implement standardized sample collection and processing protocols.

  • Timing of sample collection: In cases of acute infection or recent vaccination, samples collected too early may lack detectable antibodies. Studies have shown that some vaccinees with pre-existing flaviviral immunity fail to produce detectable IgM antibodies despite developing protective immunity .
    Mitigation: Consider the timing of sample collection relative to disease onset or intervention.

Implementing comprehensive quality control programs with well-characterized positive and negative controls helps identify and address these issues systematically.

How can automated systems improve IFA testing, and what are their limitations?

Automated computer-assisted diagnosis (CAD) systems offer several advantages and limitations for IFA testing:

Advantages:

  • Reduced subjectivity: Automated systems eliminate inter-observer variability in pattern recognition and intensity assessment, providing more consistent results .

  • Increased throughput: Automated systems can process larger numbers of samples more efficiently than manual reading, improving laboratory workflow .

  • Digital documentation: These systems create permanent digital records of images and results, facilitating quality assurance and retrospective analysis .

  • Pattern recognition algorithms: Advanced systems can recognize and classify fluorescence patterns, potentially increasing accuracy in complex pattern identification .

Limitations:

  • Validation requirements: Each automated system requires thorough validation against manual reading, with ongoing quality control to ensure consistent performance .

  • Pattern classification challenges: Some complex or mixed patterns may be difficult for automated systems to classify correctly, potentially requiring human confirmation .

  • Initial cost and maintenance: Implementation requires significant investment in equipment and software, plus ongoing maintenance costs.

  • Possible reduced sensitivity for weak positives: Some studies suggest automated systems may miss weak positive signals that experienced human readers can detect.

Current international recommendations suggest that automated systems should be validated against traditional visual reading methods, with clear protocols for handling discrepancies. While automation offers significant advantages, most experts recommend maintaining human expertise for reviewing critical or ambiguous results .

How can multiplexing be effectively implemented in IFA techniques?

Implementing effective multiplexing in IFA techniques requires careful planning and optimization:

Strategies for successful multiplexing:

  • Strategic fluorophore selection: Choose fluorophores with minimal spectral overlap to reduce bleed-through between channels. A sample experimental palette might include:

    • DAPI (460nm emission) for nuclear staining

    • FITC (520nm emission) for target 1

    • TRITC/Cy3 (605nm emission) for target 2

    • APC/Cy5 (670nm emission) for target 3

  • Antibody compatibility planning:

    • For indirect staining: Primary antibodies must be from different host species to prevent cross-reactivity of secondary antibodies.

    • For direct staining: Use directly conjugated primary antibodies to eliminate species cross-reactivity concerns .

  • Sequential staining protocols: When antibody compatibility issues arise, consider sequential staining with intermediate fixation steps between antibody applications.

  • Careful titration: Each antibody should be titrated individually before combining in multiplex protocols to determine optimal concentrations that maximize signal while minimizing background.

  • Comprehensive controls: Include single-stained controls for each fluorophore to assess bleed-through and optimize compensation settings .

Technical considerations:

  • Microscope configuration: Verify that your microscope has appropriate filter sets for each fluorophore in your multiplex panel .

  • Order of detection: When using brightfield and fluorescence techniques together, typically perform brightfield first followed by fluorescence detection.

  • Signal amplification balance: Ensure detection sensitivity is balanced across all targets by adjusting exposure times or antibody concentrations.

For complex multiplexing beyond 4-5 targets, specialized techniques like cyclic immunofluorescence or spectral unmixing may be required to overcome the limitations of conventional fluorescence microscopy.

How are automated image analysis and artificial intelligence transforming IFA interpretation?

The integration of automated image analysis and artificial intelligence (AI) is revolutionizing IFA interpretation:

  • Computer-assisted diagnosis (CAD) systems: These systems are increasingly being adopted for standardized IFA reading, offering novel features for clinical laboratories. International recommendations now address their implementation and validation .

  • Pattern recognition algorithms: Machine learning models can recognize and classify fluorescence patterns with increasing accuracy, potentially surpassing human capabilities for certain standardized patterns.

  • Consistency improvements: Studies show that CAD systems can reduce inter-observer variability, a significant limitation of traditional visual IFA reading .

  • Digital archiving and analysis: Automated systems enable comprehensive digital storage of images, facilitating retrospective analysis, quality assurance, and data sharing among researchers.

  • Validation approaches: Current recommendations emphasize the importance of validating these systems against traditional visual reading, with clear protocols for handling discrepancies .

The integration of these technologies requires balancing automation with human expertise. While AI can enhance consistency and efficiency, human oversight remains essential for reviewing critical or ambiguous results and interpreting findings in clinical context. Future developments will likely focus on improving pattern recognition for complex or mixed patterns and integrating contextual clinical information into automated interpretation systems .

What recent methodological advances have improved the sensitivity and specificity of IFA techniques?

Recent methodological advances have significantly enhanced IFA performance:

  • Standardized substrates: Improved manufacturing processes have increased the consistency of cell-based substrates, reducing batch-to-batch variation and enhancing reproducibility .

  • Novel fluorophores: Development of brighter, more photostable fluorophores has improved signal detection, particularly for low-abundance targets.

  • Enhanced detection systems: High-sensitivity cameras and improved microscope optics allow detection of weaker signals with better resolution.

  • Multiparametric analysis: Integration of multiple markers in single assays enables more comprehensive analysis of complex biological systems.

  • Biomarker combinations: Research suggests that combining multiple biomarkers can improve diagnostic accuracy. For example, studies show excellent agreement between different methods (RIA, ELISA, and f-CBA-IFA) for detecting antibodies against specific targets like muscle-specific kinase (MuSK), with f-CBA-IFA demonstrating higher agreement with RIA for positive samples .

  • Automated reading systems: Computer-assisted diagnosis (CAD) systems with sophisticated pattern recognition algorithms improve standardization and reduce inter-observer variability .

These advances are particularly valuable for challenging applications like detecting low-titer antibodies or distinguishing between closely related pathogens. The integration of these improvements requires rigorous validation, with recommendations from international expert groups providing frameworks for implementation in research and clinical settings .

What are the current consensus recommendations for optimizing IFA in research settings?

Current consensus recommendations for optimizing IFA in research settings emphasize standardization, validation, and quality assurance:

  • Substrate and reagent selection: Use well-characterized cell substrates and reagents with documented performance characteristics. For applications like ANA testing, international recommendations provide guidance on methodological aspects including substrate and conjugate selection .

  • Protocol standardization: Implement standardized protocols for sample processing, dilution schemes, incubation times, and washing steps to ensure reproducibility .

  • Comprehensive controls: Include appropriate positive and negative controls, isotype controls, and cell controls (both positive and negative for the target) in each assay run .

  • Validation approaches: Thoroughly validate new methods against established reference techniques. For example, studies comparing different antibody detection methods (such as RIA, ELISA, and f-CBA-IFA) demonstrate the importance of comprehensive validation .

  • Quality assurance programs: Participate in external quality assessment programs when available, and implement regular internal quality control measures .

  • Documentation standards: Maintain comprehensive documentation of all methodological details, including microscope settings, image acquisition parameters, and interpretation criteria .

  • Automation considerations: When implementing automated systems, establish clear protocols for validation against manual reading and for handling discrepancies .

These recommendations, supported by international expert groups including the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM), the European Autoimmune Standardization Initiative (EASI), and the International Consensus on ANA Patterns (ICAP), provide frameworks for ensuring high-quality IFA testing in both research and clinical settings .

What are the key considerations when transitioning from research IFA protocols to clinical diagnostic applications?

Transitioning IFA protocols from research to clinical diagnostic applications requires addressing several critical considerations:

  • Analytical validation: Comprehensive validation studies must demonstrate acceptable performance characteristics, including:

    • Sensitivity and specificity compared to reference methods

    • Precision (repeatability and reproducibility)

    • Analytical measurement range

    • Interfering substances

    • Clinical validation with well-characterized samples

  • Standardization: Protocols must be standardized and documented in detail, including:

    • Sample requirements and handling procedures

    • Reagent specifications and quality control

    • Precise methodological steps

    • Interpretation criteria and reporting formats

  • Quality assurance: Implement robust quality control systems, including:

    • Internal quality control materials and procedures

    • Participation in external quality assessment programs

    • Regular competency assessment of personnel

  • Regulatory compliance: Ensure compliance with relevant regulatory requirements, which vary by jurisdiction but typically include:

    • Validation documentation

    • Quality management systems

    • Personnel qualifications

    • Record-keeping requirements

    • For IFA specifically, consider recommendations from international expert groups like EFLM, EASI, and ICAP

  • Clinical utility assessment: Demonstrate the test's impact on clinical decision-making through:

    • Correlation with clinical outcomes

    • Comparative effectiveness studies

    • Assessment of positive and negative predictive values in the intended population

Quick Inquiry

Personal Email Detected
Please use an institutional or corporate email address for inquiries. Personal email accounts ( such as Gmail, Yahoo, and Outlook) are not accepted. *
© Copyright 2025 TheBiotek. All Rights Reserved.