Our standard lead time for dispatching orders is 1-3 business days after receipt. Delivery timelines may vary depending on the chosen shipping method and destination. For specific delivery information, please consult your local distributors.
Q&A
What is Rabbit anti-Sheep IgG Antibody (Biotin Conjugated) and how is it produced?
Rabbit anti-Sheep IgG Antibody (Biotin Conjugated) is a secondary antibody produced by immunizing rabbits with sheep immunoglobulin G. The antibody recognizes and binds to sheep IgG molecules, and is conjugated with biotin to enable detection via avidin-biotin or streptavidin-biotin systems. The production process typically involves several critical steps:
Immunization of rabbits with purified sheep IgG using proprietary immunization schedules designed to produce high-affinity antibodies
Collection of antiserum from hyperimmunized rabbits
Purification via affinity chromatography using sheep IgG covalently linked to agarose beads
Removal of unwanted cross-reactivities through solid phase adsorption techniques
Biotinylation process to conjugate biotin molecules to the purified antibody while preserving its specificity and affinity
The resulting biotinylated antibody contains approximately 1.5 mg active conjugate per ml and is maintained in a buffer solution containing 10 mM sodium phosphate, 0.15 M NaCl, 0.08% sodium azide, and 3 mg/ml bovine serum albumin at pH 7.8.
What structural specificity does Rabbit anti-Sheep IgG (H+L) possess compared to fragment-specific alternatives?
Rabbit anti-Sheep IgG (H+L) specificity differs significantly from fragment-specific alternatives in terms of binding targets and research applications:
Specificity Type
Target Regions
Recognition Pattern
Potential Cross-Reactivity
Ideal Applications
H+L (Heavy+Light)
Heavy and light chains of sheep IgG
Recognizes epitopes on both heavy and light chains
May cross-react with light chains of other sheep immunoglobulins
General detection of sheep IgG, broader applications
Fc Fragment Specific
Only Fc portion of sheep IgG
No reaction with F(ab) regions
Minimal cross-reactivity with F(ab) fragments
When Fc-specific detection is required, avoiding F(ab) detection
F(ab')₂ Fragment Specific
Only F(ab')₂ portion of sheep IgG
No reaction with Fc regions
Minimal cross-reactivity with Fc fragments
When F(ab')₂-specific detection is required, avoiding Fc detection
The H+L specificity provides broader reactivity by recognizing epitopes across the complete IgG molecule, making it useful for general detection purposes. In contrast, fragment-specific antibodies offer more selective targeting when particular regions of the IgG molecule must be detected or when certain cross-reactions must be avoided.
What are the optimal working concentrations for different experimental applications?
The optimal working concentration varies significantly depending on the specific application and detection system used:
Application
Recommended Concentration Range
Dilution Factor
Optimization Considerations
Immunohistochemistry
2-10 μg/ml
1:150-1:750
May require adjustment based on tissue type and fixation method
Immunofluorescence
2-10 μg/ml
1:150-1:750
Higher concentrations may be needed for weakly expressed antigens
ELISA
1:10,000-1:50,000 dilution of reconstitution concentration
1:10,000-1:50,000
Working concentration depends on primary antibody titer and antigen abundance
Western Blotting
2-10 μg/ml
1:150-1:750
May require optimization based on protein loading and transfer efficiency
In situ hybridization
2-10 μg/ml
1:150-1:750
May need adjustment based on probe type and hybridization conditions
It is strongly recommended to perform titration experiments to determine the optimal antibody concentration for each specific application and experimental system. Factors such as tissue type, antigen abundance, and detection system can significantly impact the optimal working concentration.
How does the choice between avidin-biotin complex (ABC) and labeled streptavidin-biotin (LSAB) detection systems affect experimental outcomes?
The choice between ABC and LSAB detection systems can significantly impact experimental sensitivity, specificity, and practical workflow:
Detection System
Mechanism
Advantages
Limitations
Best Applications
Avidin-Biotin Complex (ABC)
Free avidin/streptavidin bridges biotinylated antibody and biotinylated reporter enzymes
- Improved tissue penetration - Simpler protocol with fewer steps - Reduced background in certain applications
- Potentially lower signal amplification - May be more expensive
- Applications requiring better tissue penetration - Frozen sections - When background is problematic
The LSAB method is particularly advantageous when the avidin-biotin-enzyme complex in the ABC method becomes too large to penetrate the tissue effectively. Experimental considerations should include tissue type, fixation method, target abundance, and required sensitivity level.
How can background issues be minimized when using Rabbit anti-Sheep IgG in immunoassays?
Background minimization is critical for obtaining clean, interpretable results when using Rabbit anti-Sheep IgG antibodies:
Background Source
Mechanism
Mitigation Strategy
Implementation Notes
Cross-reactivity with bovine immunoglobulins
Anti-sheep IgG can cross-react with bovine IgG present in blocking agents like BSA, milk, or serum
Use Animal-Free Blocker™ solution (e.g., Cat. No. SP-5030) instead of bovine-derived blocking agents
Particularly important for ELISA and blot assays where bovine products are commonly used
Endogenous immunoglobulins in tissue
Antibody binding to native immunoglobulins in the tissue
Dilute biotinylated antibody in buffer containing 2% normal serum from the same species as the tissue
This competes with binding to endogenous immunoglobulins
Endogenous biotin in tissues
Natural biotin in tissues can bind to detection reagents
Pre-block endogenous biotin using avidin/biotin blocking kits
Especially important in biotin-rich tissues like kidney, liver, and brain
Non-specific binding
Electrostatic or hydrophobic interactions with tissue components
Include 0.1-0.3% Triton X-100 or Tween-20 in washing and dilution buffers
Helps reduce non-specific binding while preserving specific antibody-antigen interactions
High concentration of secondary antibody
Excess antibody increases non-specific binding
Optimize antibody concentration through titration experiments
The recommended range of 2-10 μg/ml should be tested to determine optimal concentration
It's worth noting that Rabbit anti-Sheep IgG antibodies from Vector Laboratories are specifically designed to minimize background through affinity purification and solid-phase adsorption techniques to remove cross-reactivities likely to interfere with specific labeling.
What are the critical storage parameters to maintain antibody functionality over time?
Proper storage is essential for maintaining antibody activity and functionality:
Storage Parameter
Recommended Conditions
Purpose
Additional Considerations
Short-term storage
2-8°C (refrigeration)
Maintains antibody stability for routine use
Suitable for antibodies in frequent use within 1-2 months
Long-term storage
-20°C or below (freezing)
Preserves antibody functionality for extended periods
Divide into small aliquots to avoid repeated freeze-thaw cycles
Freeze-thaw cycles
Minimize; avoid repeated freezing and thawing
Prevents protein denaturation and loss of activity
Each freeze-thaw cycle can reduce antibody activity by 5-20%
Storage buffer
Original buffer (typically contains stabilizers)
Maintains antibody structure and prevents degradation
Addition of 50% glycerol can help prevent freezing damage
Temperature fluctuations
Avoid; store in stable temperature environments
Prevents protein denaturation
Frost-free freezers not recommended due to temperature cycling
Reconstitution (if lyophilized)
Follow manufacturer's instructions precisely
Ensures proper solubilization and activity
Typically reconstituted with deionized water or specified buffer
For the specific case of Vector Laboratories' Rabbit anti-Sheep IgG Antibody (Biotin conjugated), the recommended storage is at 2-8°C for short-term and frozen for long-term storage. The product is supplied in a solution containing 10 mM sodium phosphate, pH 7.8, 0.15 M NaCl, 0.08% sodium azide, and 3 mg/ml bovine serum albumin, which helps maintain stability.
How does this antibody perform in multiplexed detection systems and what are the optimization strategies?
Multiplexed detection using Rabbit anti-Sheep IgG Antibody (Biotin conjugated) requires careful planning and optimization:
Multiplexing Aspect
Technical Considerations
Optimization Strategies
Advanced Applications
Cross-reactivity management
Potential cross-reaction between detection systems
- Use highly cross-adsorbed secondary antibodies - Employ sequential detection protocols - Consider nanobody alternatives for reduced cross-reactivity
Multicolor immunofluorescence with primary antibodies from different species
Signal separation
Distinguishing between multiple targets
- Use spectrally distinct fluorophores with streptavidin conjugates - Implement spectral unmixing for overlapping signals - Consider sequential staining protocols
Ensuring comparable signal intensity across targets
- Adjust concentration of each secondary antibody independently - Calibrate streptavidin-reporter concentrations - Use digital image analysis for post-acquisition normalization
Quantitative comparison of multiple targets within the same sample
Background management
Increased background in multiplexed systems
- Implement stringent blocking procedures - Use highly purified antibodies - Consider tyramide signal amplification for specific targets
Applications requiring high sensitivity and low background
Recent advances include using biotinylated anti-species nanobodies as alternatives to conventional polyclonal secondary antibodies, which can offer single-step multicolor labeling, improved tissue penetration, and reduced labeling distance for superresolution microscopy applications.
What are the critical quality control parameters researchers should verify when using biotinylated antibodies in sensitive detection systems?
Researchers should verify several critical quality control parameters to ensure reliable results:
Quality Control Parameter
Assessment Method
Acceptance Criteria
Impact on Experimental Outcome
Degree of biotinylation
HABA assay or mass spectrometry
Optimal biotin:protein ratio between 3:1 and 7:1
Over-biotinylation can reduce antibody affinity and increase non-specific binding; under-biotinylation reduces detection sensitivity
Antibody specificity
Western blot against purified sheep IgG and control IgGs
Single band at expected molecular weight for sheep IgG; minimal cross-reactivity
Poor specificity leads to false positive signals and high background
Unaccounted cross-reactivity can lead to misinterpretation of results
Signal-to-noise ratio
Titration curves in relevant application
Consistent signal differentiation between positive and negative controls
Low signal-to-noise ratio reduces assay sensitivity and reliability
Lot-to-lot consistency
Comparative analysis between lots
Consistent performance metrics across production lots
Lot variations can impact reproducibility of longitudinal studies
Additionally, researchers should conduct appropriate controls including:
Primary antibody omission control
Secondary antibody alone control
Blocking reagent control
Isotype-matched control antibody
Positive tissue control with known expression of the target
These quality control measures are especially important when using biotinylated antibodies in quantitative applications or when working with rare or valuable samples.
How does biotin-streptavidin detection compare with direct enzyme or fluorophore conjugation for sensitivity and specificity?
Different detection systems offer varying advantages depending on research needs:
Detection System
Signal Amplification
Sensitivity
Background Potential
Workflow Complexity
Best Applications
Biotin-Streptavidin
High (multiple biotin binding sites per streptavidin)
Recent research indicates that nanobody-based detection systems can offer significantly reduced fluorophore offset distances in superresolution microscopy applications, making them superior alternatives to traditional secondary antibodies for certain advanced imaging applications.
What are the advantages and limitations of using different IgG fragment-specific antibodies in research applications?
Different fragment-specific antibodies offer unique advantages for specific research scenarios:
The choice between these fragment-specific antibodies should be guided by the specific research question, potential interfering factors in the experimental system, and the need for detection of specific structural elements of sheep IgG molecules.
Quick Inquiry
Personal Email Detected
Please use an institutional or corporate email address for inquiries. Personal email accounts ( such as Gmail, Yahoo, and Outlook) are not accepted. *