YET1 Antibody

Shipped with Ice Packs
In Stock

Product Specs

Buffer
Preservative: 0.03% Proclin 300
Constituents: 50% Glycerol, 0.01M Phosphate Buffered Saline (PBS), pH 7.4
Form
Liquid
Lead Time
Made-to-order (14-16 weeks)
Synonyms
YET1; YKL065C; YKL331; Endoplasmic reticulum transmembrane protein 1
Target Names
YET1
Uniprot No.

Target Background

Function
This antibody targets YET1, a protein that may play a role in the anterograde transport of membrane proteins from the endoplasmic reticulum to the Golgi apparatus.
Database Links

KEGG: sce:YKL065C

STRING: 4932.YKL065C

Protein Families
BCAP29/BCAP31 family
Subcellular Location
Endoplasmic reticulum membrane; Multi-pass membrane protein.

Q&A

What are the minimum requirements for proper antibody characterization in scientific research?

Proper antibody characterization requires documentation of four essential elements: (i) confirmation that the antibody binds to the target protein; (ii) verification that the antibody binds to the target protein within complex protein mixtures (such as cell lysates or tissue sections); (iii) demonstration that the antibody does not cross-react with proteins other than the intended target; and (iv) validation that the antibody performs as expected under the specific experimental conditions employed in the assay . These requirements form the foundation of antibody validation and should be met before an antibody is utilized in critical experiments.

How do knockout (KO) cell lines contribute to antibody validation?

Knockout cell lines represent a gold standard approach for antibody validation. Recent studies by YCharOS have demonstrated that KO cell lines provide superior control conditions compared to traditional methods, particularly for Western blot applications and even more significantly for immunofluorescence imaging . In knockout validation, antibodies are tested against cell lines where the target protein has been genetically eliminated. This approach provides unambiguous evidence of antibody specificity, as any signal detected in the knockout line indicates non-specific binding. The superiority of this approach has been documented in extensive studies comparing multiple validation methodologies .

What is the current state of commercially available antibodies in terms of quality and reliability?

Research indicates that approximately 50% of commercial antibodies fail to meet basic characterization standards, resulting in estimated financial losses of $0.4–1.8 billion annually in the United States alone . A comprehensive analysis of 614 antibodies targeting 65 proteins revealed that only 50–75% of the protein set was covered by at least one high-performing commercial antibody, depending on the application . This indicates significant quality issues within the antibody market, though it also suggests that commercial catalogs contain specific and renewable antibodies for more than half of the human proteome .

What is the recommended approach for antibody titration in flow cytometry applications?

Proper antibody titration for flow cytometry involves a systematic process to determine the optimal concentration that maximizes signal-to-noise ratio. The methodology includes:

  • Preparing serial dilutions of the antibody

  • Staining a consistent number of cells with each dilution

  • Analyzing signal intensity and background for each dilution

  • Calculating the signal-to-noise ratio

  • Selecting the concentration that provides maximum specific signal with minimal background

Antibody titration is particularly critical in multicolor panel design, as demonstrated in the optimization of 21-color panels using the ZE5 Cell Analyzer, where proper titration contributes significantly to the integrity of multi-color experimental design . The titration process should account for antigen density and fluorophore brightness to achieve optimal resolution.

How should researchers approach the design of high-parameter flow cytometry panels to minimize spectral overlap?

Designing high-parameter flow cytometry panels requires careful consideration of several factors to minimize spectral overlap and optimize population resolution:

  • Fluorophore-antibody combinations: Select combinations that optimize population resolution while minimizing spectral spillover and plot spreading. Consider fluorophore brightness in relation to antigen density .

  • Instrument optical design: Account for the specific optical design and filter configuration of your instrument, as these affect detection efficiency and dynamic range .

  • Colocalized markers: Give additional consideration to antibodies that detect markers colocalized to the same cell (e.g., CD3 and CD4), ensuring they are balanced for antigen density relative to dye brightness .

  • PMT standardization: After initial photomultiplier tube standardization, fine-tune detector voltages to minimize spillover while keeping coefficients of variation (CVs) at the lowest values .

  • Dynamic range boundaries: Maintain experimental populations within usable dynamic range boundaries determined by reference standards (e.g., 8-peak bead references) .

In an optimized 21-color panel design, researchers achieved compensation values mostly under 10% (with the highest just over 70%) and minimal digital plot spreading after compensation .

What methodological approaches can be used to validate antibodies for specific applications like Western blotting versus immunofluorescence?

Validation approaches should be tailored to the specific application as antibody performance can vary significantly between techniques:

ApplicationRecommended Validation MethodsKey Considerations
Western Blot- KO cell line testing
- Recombinant protein controls
- Molecular weight verification
- Blocking peptides
- Detection of denatured proteins
- Linear epitopes
- Reducing vs. non-reducing conditions
Immunofluorescence- KO cell line imaging
- siRNA knockdown
- Subcellular localization verification
- Colocalization with orthogonal markers
- Detection of native proteins
- Conformational epitopes
- Fixation/permeabilization effects
- Autofluorescence considerations
Immunoprecipitation- KO cell line validation
- Mass spectrometry validation
- Reciprocal co-IP
- Non-specific binding controls
- Protein-protein interactions
- Buffer conditions
- Stringency of washes
- Detection of complexes

YCharOS has developed consensus protocols for Western blot, immunoprecipitation, and immunofluorescence techniques through collaborations with 12 industry partners and academic researchers . These standardized protocols have been published and can be widely used in antibody characterization efforts .

How does the maturation of antibodies correlate with their antiviral activity, and what implications does this have for neutralizing antibody development?

Research on Nipah virus (NiV) neutralizing antibodies has revealed a direct correlation between antibody maturation and antiviral efficacy . Following affinity maturation, antibodies derived from the parental antibody NiV41 demonstrated enhanced cross-reactivity against both NiV and Hendra virus (HeV), while antibodies based on NiV42 maintained specificity exclusively to NiV . In vivo testing of NiV41 and its mature form (41-6) demonstrated protective efficacy against lethal NiV challenge in hamsters .

Cryo-EM structural analysis at 2.88 Å resolution revealed that the mature antibody 41-6 blocks the receptor binding interface of the tetrameric receptor binding protein (RBP) of NiV . This structural insight explains the neutralizing mechanism and provides a foundation for rational design of therapeutic antibodies.

The correlation between maturation and efficacy suggests that engineered maturation processes could enhance the therapeutic potential of candidate antibodies, particularly for emerging pathogens. This approach could accelerate the development of broadly neutralizing antibodies with potential applications in immunotherapy against priority pathogens like NiV, for which no approved treatments currently exist .

What strategies can be employed to overcome the challenges of reproducibility in antibody-based research?

Addressing the reproducibility crisis in antibody-based research requires multifaceted approaches:

  • Standardized validation protocols: Implement consensus protocols for key applications like those developed by YCharOS in collaboration with industry partners .

  • Comprehensive reporting: Document all relevant antibody information, including catalog number, lot number, dilution, incubation conditions, and validation methods.

  • Use of Research Resource Identifiers (RRIDs): Employ RRIDs to unambiguously identify antibodies in publications and databases .

  • Preference for recombinant antibodies: Recent studies show that recombinant antibodies outperform both monoclonal and polyclonal antibodies across multiple assays .

  • Community validation efforts: Participate in community-based validation initiatives to share data and experiences with specific antibodies.

  • Proper controls: Include appropriate controls in every experiment, particularly knockout/knockdown controls and fluorescence-minus-one (FMO) controls for flow cytometry .

  • Independent validation: Verify key findings with orthogonal methods or alternative antibodies targeting different epitopes of the same protein.

Implementation of these strategies can significantly reduce the estimated $0.4–1.8 billion annual losses attributed to poor antibody quality and improve scientific reproducibility .

What are the best practices for gating strategies in high-parameter flow cytometry using the ZE5 Cell Analyzer?

Optimized gating strategies for high-parameter flow cytometry using the ZE5 Cell Analyzer should follow a hierarchical approach:

  • Initial population identification: Begin by placing a region around the white blood cell population to exclude red cell debris in a plot of forward scatter (FSC) versus side scatter (SSC) .

  • Doublet discrimination: Implement doublet exclusion using FSC-A versus FSC-W parameters to ensure analysis of single cells only .

  • Viability assessment: Isolate live singlet cells using a viability dye such as Zombie UV, plotting the viability marker against FSC-H .

  • Major lineage separation: Separate live singlet cells into major populations (T cells, B cells, myeloid cells) using lineage markers such as CD3 versus CD20 .

  • Subset identification: Further subdivide major populations into functional subsets. For example, CD4+ T cells can be separated into central memory, naïve, and effector memory populations using CD45RA versus CD197 .

This approach allowed researchers to identify more than 26 well-defined subpopulations simultaneously in an optimized 21-color panel, providing quantification of both major and minor cell types .

How can researchers effectively use fluorescence-minus-one (FMO) controls in multicolor flow cytometry experiments?

Fluorescence-minus-one (FMO) controls play a crucial role in establishing accurate gating boundaries in multicolor flow cytometry:

  • Purpose: FMO controls help distinguish between true positive signals and spillover-induced background, particularly important in high-parameter panels where spectral overlap becomes increasingly complex.

  • Implementation: For each fluorochrome in your panel, prepare a control sample stained with all fluorochromes except the one being controlled. This reveals the combined contribution of all other fluorochromes to the channel of interest.

  • Prioritization: While including FMO controls for all parameters is ideal during panel development, this may not be practical for routine experiments. Prioritize FMO controls for markers that define rare populations or those with continuous expression patterns rather than distinct positive/negative separation .

  • Exclusion criteria: Once a panel is optimized, some FMO controls may be excluded if they are not required for gating, as determined during the experimental design phase .

  • Interpretation: Use FMO controls to set the boundary between positive and negative populations, not as a measure of non-specific binding (which requires isotype controls).

In the optimized 21-color panel described, researchers initially included FMO controls for most fluorophores during experimental design but later excluded some that were determined unnecessary for accurate gating .

What technologies and initiatives are advancing antibody characterization on a proteome-wide scale?

Several technologies and initiatives are making significant contributions to proteome-wide antibody characterization:

  • YCharOS initiative: Launched in 2020 at the Montreal Neurological Institute as part of the Structural Genomics Consortium (SGC), YCharOS focuses on characterizing existing antibodies using standardized protocols and knockout cell lines . As of March 2023, YCharOS had tested more than 1,000 antibodies and published 96 antibody characterization reports .

  • Knockout cell line repositories: The development of comprehensive libraries of knockout cell lines for validation studies has accelerated antibody characterization efforts.

  • High-throughput screening platforms: Advanced platforms enable rapid testing of antibodies across multiple applications simultaneously.

  • Recombinant antibody technologies: New approaches for generating recombinant antibodies with defined sequences have improved reproducibility and performance .

  • Industry-academia partnerships: Collaborations between antibody vendors and research institutions have proven valuable for validation efforts, with vendors proactively removing approximately 20% of antibodies that failed testing and modifying the proposed applications for approximately 40% .

  • Standardized protocols: The development and adoption of consensus protocols for antibody characterization, as exemplified by the YCharOS initiative's collaboration with 10 leading antibody manufacturers, has established common methodological approaches across the field .

These initiatives collectively address the challenges of proteome-wide antibody characterization, though scaling these efforts remains a significant challenge .

What are the implications of the finding that approximately 12 publications per protein target include data from antibodies that fail to recognize their target?

The revelation that an average of approximately 12 publications per protein target include data from antibodies that fail to recognize the relevant target protein has profound implications for research integrity and scientific progress:

Addressing this issue requires concerted efforts from multiple stakeholders, including researchers, institutions, journals, antibody vendors, and funding agencies .

How do recombinant antibodies compare to monoclonal and polyclonal antibodies in performance across different applications?

Comparative analysis reveals distinct performance profiles across antibody types:

Antibody TypeAdvantagesLimitationsRelative Performance
Recombinant- Defined sequence
- Renewable resource
- Minimal batch variation
- Customizable properties
- Higher production cost
- May require specialized expression systems
- Limited commercial availability for some targets
Superior performance across most applications
Monoclonal- Single specificity
- Relatively consistent between batches
- Well-established production methods
- Hybridoma instability
- Limited epitope coverage
- May lose activity during conjugation
Intermediate performance in most applications
Polyclonal- Multiple epitope recognition
- High sensitivity
- Tolerant of sample preparation variations
- Batch-to-batch variability
- Limited renewable supply
- Higher background in some applications
Variable performance; generally lower specificity

Recent comprehensive testing by YCharOS demonstrated that recombinant antibodies outperformed both monoclonal and polyclonal antibodies, on average, across all assays evaluated . This finding supports the ongoing transition toward recombinant antibody technologies in research applications.

What technical considerations are essential when optimizing detector voltages for multicolor flow cytometry?

Optimizing detector voltages for multicolor flow cytometry requires a systematic approach to balance sensitivity, resolution, and spillover:

This meticulous approach to voltage optimization is essential for generating high-quality data in complex multicolor flow cytometry experiments.

What key recommendations should researchers follow to enhance reproducibility in antibody-based research?

Based on the current state of antibody research and characterization efforts, researchers should adhere to the following recommendations:

Implementation of these recommendations will enhance the reproducibility and reliability of antibody-based research, ultimately accelerating scientific progress and reducing resource waste.

How might current antibody characterization efforts inform the development of improved antibody-based therapeutics?

The methodologies and insights generated through antibody characterization initiatives have significant implications for therapeutic antibody development:

  • Structural insights: Detailed structural studies, such as the 2.88 Å Cryo-EM analysis of antibody-antigen complexes, provide crucial information about binding mechanisms and epitope targeting that can inform rational design of therapeutic antibodies .

  • Affinity maturation correlations: Understanding the relationship between antibody maturation and functional efficacy, as demonstrated in the Nipah virus studies, can guide optimization strategies for therapeutic antibodies .

  • Cross-reactivity assessment: Comprehensive characterization of antibody cross-reactivity profiles can identify candidates with broader therapeutic potential across related pathogens or targets .

  • Performance prediction: The validation methods developed for research antibodies can be adapted to better predict the in vivo performance of therapeutic candidates, potentially reducing late-stage clinical failures.

  • Quality control standards: Rigorous characterization standards established for research antibodies can inform improved quality control processes for therapeutic antibody production.

  • Target validation: More reliable antibody-based research will enhance target validation efforts, providing stronger foundations for therapeutic development programs.

Quick Inquiry

Personal Email Detected
Please use an institutional or corporate email address for inquiries. Personal email accounts ( such as Gmail, Yahoo, and Outlook) are not accepted. *
© Copyright 2025 TheBiotek. All Rights Reserved.